Loading...
The RNA Library Prep AmpliSeq for Illumina Comprehensive Panel v3 is part of the AmpliSeq for Illumina Comprehensive Panel protocols that include the following functionality:
Preconfigured AmpliSeq for Illumina Comprehensive Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.Automated assignment of QC Pass/Fail, based on user-selected threshold values.
Protocol Type = Library Prep
Next Steps Configuration
Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Desired Concentration (ng/uL)
Numeric
Range = 0 To 1000
Directions
Multiline Text
Read Only
Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Sample Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Master Step Name = Qubit (AmpliSeq for Illumina v1.1)
Step Type = Standard QC
Measurement Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Criteria 1 - Operator
Text
Default = >=
Criteria 1 - Source Data Field
Text
Default = Concentration
Criteria 1 - Threshold Value
Numeric
Criteria 2 - Operator
Text
Default = <=
Criteria 2 - Source Data Field
Text
Default = Concentration
Criteria 2 - Threshold Value
Numeric
Step File Placeholders
Log - Automatically attached
QC Log File - Automatically attached
QC Result File - Automatically attached
Upload File - Manually uploaded
Sample Table
Enable QC Flags = Yes
Sample Display Default = Expand
Well Sort Order = Row
File Column Options
File Column Display = Hide
File Attachment Method = Auto
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Sample Name
Built-in
Measurement
Concentration
Numeric
Decimal Places Displayed = 2
Measurement
Conc. Units
Text
Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Desired Concentration (ng/uL)
Numeric
Range = 0 To 1000
Directions
Multiline Text
Read Only
Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Sample Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Master Step Name = Reverse Transcribe RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq cDNA Synthesis for Illumina
Supplier = Illumina
Catalog Number = 20022654
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
5X AmpliSeq cDNA Reaction Mix (uL)
Numeric
Decimal Places Displayed = 1
10X AmpliSeq RT Enzyme Mix (uL)
Numeric
Decimal Places Displayed = 1
Desired Concentration (ng/uL)
Numeric
Read Only
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 1
Prep Input Amount (ng)
Numeric
Default = 2
Range = 2 To 1000
Prep Input Volume (uL)
Numeric
Decimal Places Displayed = 2
Recommended Prep Input (ng)
Multiline Text
Read Only
Default = Each reaction requires 1-100 ng of DNase-treated total RNA. The recommended input is 10 ng RNA.
Thermal Cycler Program
Text
Read Only
Default = RT
Total Samples
Numeric
Default = 0
Decimal Places Displayed = 0
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Sample Name
Built-in
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Master Step Name = Amplify cDNA Targets (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 2
Naming Convention = {InputItemName}_{OutputItemSubsetNumber}
Reagent Kits
AmpliSeq Comprehensive Panel v3 for Illumina
Supplier = Illumina
Catalog Number = 20019109
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
5X AmpliSeq HiFi Mix (uL)
Numeric
Decimal Places Displayed = 2
Instructions - Comprehensive Panel v3
Multiline Text
Default = Add 2 µl 5X AmpliSeq Comprehensive RNA Panel v3 Pool 1 (red cap) to the first well. Add 2 µl 5X AmpliSeq Comprehensive RNA Panel v3 Pool 2 (red cap) to the second well.
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
Thermal Cycler Program
Text
Default = AMP_RNA
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Master Step Name = Partially Digested Amplicons with Pooling (AmpliSeq for Illumina v1.1)
Step Type = Pooling
Aliquot Generation = Fixed, 1
Naming Convention = {PoolName}
Reagent Kits
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Label Uniqueness = Off
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Defaults
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Thermal Cycler Program
Text
Default = FUPA
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Queue for Plate Transfer
Text
Default = Transfer Amplicons
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
The Equalizer Workflow AmpliSeq for Illumina Comprehensive Panel v3 is part of the AmpliSeq for Illumina Comprehensive Panel protocols that include the following functionality:
Preconfigured AmpliSeq for Illumina Comprehensive Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.Automated assignment of QC Pass/Fail, based on user-selected threshold values.
Protocol Type = Library Prep
Next Steps Configuration
Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
70% EtOH Prep Date
Date
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Group of Defaults
Step Data
Group of Defaults = Equalizer Workflow
Master Step Fields
Field Name
Field Type
Options
Additional Options and Dropdown Items
1X Lib AMP Mix (uL)
Numeric
Decimal Places Displayed = 2
10X Library Amp Primers (uL)
Numeric
Decimal Places Displayed = 2
Thermal Cycler Program
Text Dropdown
Custom Entries
Presets
AMP_7
EQUAL
AMP
Total Samples
Numeric
Default = 0
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Master Step Name = Perform Capture and Clean Up (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Master Step Name = Elute Library (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Thermal Cycler Program
Text
Default = ELUTE
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
The Standard Workflow AmpliSeq for Illumina Comprehensive Panel v3 is part of the AmpliSeq for Illumina Comprehensive Panel protocols that include the following functionality:
Preconfigured AmpliSeq for Illumina Comprehensive Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.Automated assignment of QC Pass/Fail, based on user-selected threshold values.
Protocol Type = Library Prep
Next Steps Configuration
Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
70% EtOH Prep Date
Date
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Group of Defaults
Step Data
Group of Defaults = Standard Workflow
Master Step Fields
Field Name
Field Type
Options
Additional Options and Dropdown Items
1X Lib AMP Mix (uL)
Numeric
Decimal Places Displayed = 2
10X Library Amp Primers (uL)
Numeric
Decimal Places Displayed = 2
Thermal Cycler Program
Text Dropdown
Custom Entries
Presets
AMP_7
EQUAL
AMP
Total Samples
Numeric
Default = 0
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Master Step Name = Perform Second Clean Up (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
70% EtOH Prep Date
Date
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in