RNA Library Prep v1.1
Overview
The RNA Library Prep AmpliSeq for Illumina Immune Repertoire Panel is part of the AmpliSeq for Illumina Immune Repertoire Panel protocols that include the following functionality:
Preconfigured AmpliSeq for Illumina Immune Repertoire Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.
Automatic placement of samples when necessary.
Automated assignment of QC Pass/Fail, based on user-selected threshold values.
A routing script that allows sequencing of libraries using any Illumina sequencing instrument.
Protocol 1: RNA Library Prep (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Protocol Type = Library Prep
Next Steps Configuration

Step 1: Dilute RNA (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations

Copy Concentration and Set Sample Volume
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Group of Defaults
Immune Repertoire Panel
Directions = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.
TCR beta-SR Panel
Default = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.
Step Data
Group of Defaults = Immune Repertoire Panel
Master Step Fields
Field Name
Field Type
Options
Additional Options and Dropdown Items
Desired Concentration (ng/uL)
Numeric
Range = 0 To 1000
Directions
Multiline Text
Read Only
Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Sample Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Step 2: Qubit (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Qubit (AmpliSeq for Illumina v1.1)
Step Type = Standard QC
Measurement Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations

Set Next Step and Copy Concentration
Trigger Location = Record Details
Trigger Style = Automatic upon exit
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Criteria 1 - Operator
Text
Default = >=
Criteria 1 - Source Data Field
Text
Default = Concentration
Criteria 1 - Threshold Value
Numeric
Criteria 2 - Operator
Text
Default = <=
Criteria 2 - Source Data Field
Text
Default = Concentration
Criteria 2 - Threshold Value
Numeric
Step File Placeholders
Log - Automatically attached
QC Log File - Automatically attached
QC Result File - Automatically attached
Upload File - Manually uploaded
Sample Table
Enable QC Flags = Yes
Sample Display Default = Expand
Well Sort Order = Row
File Column Options
File Column Display = Hide
File Attachment Method = Auto
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Sample Name
Built-in
Measurement
Concentration
Numeric
Decimal Places Displayed = 2
Measurement
Conc. Units
Text
Step 3: Dilute RNA to Final Concentration (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Dilute RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Automations

Copy Concentration and Set Sample Volume
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Group of Defaults
Immune Repertoire Panel
Directions = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.
TCR beta-SR Panel
Default = If enough RNA is available, dilute to intermediate concentration ~20-1000 ng/uL.
Step Data
Group of Defaults = Immune Repertoire Panel
Master Step Fields
Field Name
Field Type
Options
Additional Options and Dropdown Items
Desired Concentration (ng/uL)
Numeric
Range = 0 To 1000
Directions
Multiline Text
Read Only
Default = If enough RNA is available, dilute to intermediate concentration ~20-50 ng/uL.
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Sample Name
Built-in
Derived Sample
Sample Volume (uL)
Numeric
Decimal Places Displayed = 2
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Step 4: Reverse Transcribe (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Reverse Transcribe RNA (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq cDNA Synthesis for Illumina
Supplier = Illumina
Catalog Number = 20022654
Website = www.illumina.com
Automations

Copy Concentration, Total Volume and Input Amount
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Calculate Input Amount - Immune Repertoire Panel
Trigger Location = Record Details
Trigger Style = Manual button
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Placement = Enabled
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Column
Destination Containers
96 well plate
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
5X AmpliSeq cDNA Reaction Mix (uL)
Numeric
Decimal Places Displayed = 1
10X AmpliSeq RT Enzyme Mix (uL)
Numeric
Decimal Places Displayed = 1
Desired Concentration (ng/uL)
Numeric
Read Only
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 1
Prep Input Amount (ng)
Numeric
Default = 2
Range = 2 To 1000
Prep Input Volume (uL)
Numeric
Decimal Places Displayed = 2
Thermal Cycler Program
Text
Read Only
Default = RT
Total Samples
Numeric
Default = 0
Decimal Places Displayed = 0
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
Concentration
Numeric
Required Field
Decimal Places Displayed = 2
Derived Sample
Conc. Units
Text
Required Field
Derived Sample
Input Amount (ng)
Numeric
Decimal Places Displayed = 0
Derived Sample
Sample Name
Built-in
Derived Sample
Total Volume (uL)
Numeric
Decimal Places Displayed = 2
Step 5: Amplify cDNA Targets (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Amplify cDNA Targets Standard (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq Immune Repertoire Panel for Illumina
Supplier = Illumina
Catalog Number = 20024479
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Automations

Set Sample Type and Calculate Master Mix - Immune Repertoire Panel
Trigger Location = Record Details
Trigger Style = Automatic upon entry
Routing cDNA - TCRbeta SR
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Routing Samples - Myeloid Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Routing Samples - TCRbeta SR Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
5X AmpliSeq HiFi Mix (uL)
Numeric
Decimal Places Displayed = 2
5X AmpliSeq Immune Repertoire Panel (uL)
Numeric
Decimal Places Displayed = 1
Nuclease-free water (uL)
Numeric
Decimal Places Displayed = 2
PCR Cycles
Text
Thermal Cycler Program
Text
Default = AMP_RNA
Total Samples
Numeric
Default = 0
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Step 6: Partially Digested Amplicons (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Partially Digested Amplicons (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Automations

Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Thermal Cycler Program
Text
Default = FUPA
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Project
Project Name
Built-in
Step 7: Ligate Indexes (AmpliSeq for Illumina Immune Repertoire Panel v1.1)
Master Step Name = Ligate Indexes (AmpliSeq for Illumina v1.1)
Step Type = Add Labels
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Automations

Route AmpliSeq Samples - Immune Repertoire Panel
Trigger Location = Step
Trigger Style = Automatic upon exit
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - BRCA
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - Childhood Cancer Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - CHP v2
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - CP
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - Custom DNA Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - Focus Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - Immune Response Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples - Myeloid Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Route AmpliSeq Samples -Transcriptome Human GEx Panel
Trigger Location = Not Used
ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.
Queue/Ice Bucket
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Container
Container Name
Built-in
Container
LIMS ID (Container)
Built-in
Container
Well
Built-in
Derived Sample
Sample Name
Built-in
Derived Sample
Waiting
Built-in
Project
Project Name
Built-in
Placement = Enabled
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Row
Destination Containers
96 well plate
Add Labels
Label Groups
AmpliSeq CD Indexes Set A for Illumina
AmpliSeq CD Indexes Set B for Illumina
AmpliSeq CD Indexes Set C for Illumina
AmpliSeq CD Indexes Set D for Illumina
AmpliSeq UD Indexes for Illumina (24 Indexes)
Record Details
Step Data (Master Step Fields)
Field Name
Field Type
Options
Additional Options and Dropdown Items
Thermal Cycler Program
Text
Default = LIGATE
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Category
Field Name
Field Type
Options
Additional Options and Dropdown Items
Derived Sample
AmpliSeq Workflow
Text Dropdown
Required Field
Presets
Standard Workflow
Equalizer Workflow
Derived Sample
Sample Name
Built-in
Last updated
Was this helpful?