iLASS Infinium Genotyping Assay v1.1
Last updated
Last updated
Protocol Type = Sample Prep
Next Steps Configuration
Master Step Name = Make WGA (ILASS Infinium Genotyping Assay v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Instrument Types
Hamilton Star
Vendor = Hamilton
Reagent Kits
AAX-Infinium
Supplier = Illumina
MA1-Infinium
Supplier = Illumina
MA2-Infinium
Supplier = Illumina
Sample Grouping = Group by Containers
Well Sort Order = Column
Placement Pattern = Same Shape
Destination Containers
96 well plate
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Sample Table (Global Step Fields)
Container
Master Step Name = Amplify WGA (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Sample Table (Global Step Fields)
Derived Sample
Master Step Name = Fragment DNA (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Instrument Types
Tecan EVO
Vendor = Tecan
Reagent Kits
FMS-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Master Step Name = Precipitate DNA (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Instrument Types
Tecan EVO
Vendor = Tecan
Reagent Kits
PM1-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Sample Table (Global Step Fields)
Derived Sample
Master Step Name = Resuspend DNA (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Instrument Types
Tecan EVO
Vendor = Tecan
Reagent Kits
IHX-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Protocol Type = Sample Prep
Next Steps Configuration
Master Step Name = Prepare Hyb Chamber (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Reagent Kits
PB2-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Master Step Name = Hybridize DNA to the BeadChip (ILASS Infinium Genotyping Assay v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Instrument Types
Tecan EVO
Vendor = Tecan
Sample Grouping = Group by Containers
Well Sort Order = Row
Placement Pattern = Row
Destination Containers
Infinium Genotyping Array EX-24
Infinium Genotyping Array EX-48
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Master Step Name = Wash BeadChips (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Reagent Kits
PB1-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Master Step Name = Extend and Stain BeadChips (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Instrument Types
Tecan EVO
Vendor = Tecan
Reagent Kits
ATX-Infinium
Supplier = Illumina
EML-Infinium
Supplier = Illumina
LX1-Infinium
Supplier = Illumina
LX2-Infinium
Supplier = Illumina
PB1-Infinium
Supplier = Illumina
STX-Infinium
Supplier = Illumina
XC3-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Sample Table (Global Step Fields)
Derived Sample
Master Step Name = Wash and Coat BeadChips (ILASS Infinium Genotyping Assay v1.1)
Step Type = No Outputs
Reagent Kits
PB1-Infinium
Supplier = Illumina
XC4-Infinium
Supplier = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
AssayRunLog - Manually uploaded
Sample Table (Global Step Fields)
Derived Sample
Protocol Type = Other
Next Steps Configuration
Master Step Name = Image Infinium BeadChip on iScan (ILASS Infinium Genotyping Assay v1.1)
Step Type = Analysis
Derived Sample Generation = Fixed, 1
Instrument Types
iScan
Vendor = Illumina
Step Data (Master Step Fields)
Step File Placeholders
Scan Log - Manually uploaded
Run Metrics File - Manually uploaded
Sample Table (Global Step Fields)
Derived Sample
Measurement
Protocol Type = Sample Prep
Next Steps Configuration
Master Step Name = Invoke Infinium Analysis (ILASS Infinium Genotyping Assay v1.1)
Step Type = Analysis
Derived Sample Generation = Fixed, 1
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
Analysis Report - Manually uploaded
Sample Table (Global Step Fields)
Derived Sample
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Plate Transfer Plan
Multiline Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
Related Source Container
Text
Related WGA Container
Text
Step Run History
Multiline Text
Experiment Name
Text
Read Only
Product Type
Text
Read Only
Last Run Datetime
Text
Read Only
IsInProgress
Toggle Switch
Read Only
Default = No
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Instruction Notes
Multiline Text
Read Only
Default = Incubate the WGA plate in the Illumina Hybridization Oven for 20–24 hours at 37°C.
Field Name
Field Type
Options
Additional Options and Dropdown Items
Source DNA Plate Barcode
Text
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Instruction Notes
Multiline Text
Read Only
Plate Transfer Plan
Multiline Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
100% 2-Propanol Prep Date
Date
Batch ID
Text
Read Only
Comment
Multiline Text
Field Name
Field Type
Options
Additional Options and Dropdown Items
IsRecombined
Toggle Switch
Default = No
Source DNA Plate Barcode
Text
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Instruction Notes
Multiline Text
Read Only
Default = Add 400 µl PB2 to the top and bottom wells of each beadchip subchamber in the hybridization chamber.
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Plate Transfer Plan
Multiline Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Instruction Notes
Multiline Text
Read Only
Default = Fill two wash dish with 200ml PB1 each and labelled Wash 1 and Wash2
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Field Name
Field Type
Options
Additional Options and Dropdown Items
IsRecombined
Toggle Switch
Default = No
Source DNA Plate Barcode
Text
Field Name
Field Type
Options
Additional Options and Dropdown Items
Batch ID
Text
Read Only
Comment
Multiline Text
Instruction Notes
Multiline Text
Read Only
Default = Add 310 ml PB1 to the PB1 wash dish. Add 310 ml XC4 to the XC4 wash dish.
Field Name
Field Type
Options
Additional Options and Dropdown Items
Array Instrument
Text
Default = iScan
Field Name
Field Type
Options
Additional Options and Dropdown Items
BeadChip Barcode
Text
Read Only
Instrument Type
Text
Read Only
Instrument
Text
Read Only
Instrument Run ID
Text
Read Only
Run Start Time
Text
Read Only
Run Complete Time
Text
Read Only
Run Status
Text
Read Only
Failure Reason
Text
Read Only
Comment
Multiline Text
Log
Multiline Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
BeadChip Name
Text
Read Only
Sample Section
Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
Imaging Result
Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
Analysis Configuration ID
Text
Required Field
Analysis Run Name
Text
Required Field
Analysis Start Time
Text
Read Only
Analysis Complete Time
Text
Read Only
Analysis Status
Text
Read Only
Log
Multiline Text
Read Only
Field Name
Field Type
Options
Additional Options and Dropdown Items
BeadChip Name
Text
Read Only
Sample Section
Text
Read Only