Standard v1.1

Overview

The Standard Workflow AmpliSeq for Illumina BRCA Panel is part of the preconfigured AmpliSeq for Illumina BRCA Panel protocols supporting the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.

This protocol includes the following:

  • Preconfigured AmpliSeq for Illumina BRCA Panel protocol that supports the preparation of uniquely indexed libraries of genomic DNA using the AmpliSeq for Illumina workflow.

  • Automated calculation of sample and buffer volumes.

  • Automated calculation or display of reagents at every step in the protocol.

  • Automatic step transition when required.

  • Automatic placement of samples when necessary.

  • Automated assignment of QC Pass/Fail, based on user-selected threshold values.

  • A routing script that allows sequencing of libraries using any Illumina sequencing instrument.

Protocol 1: Standard Workflow (AmpliSeq for Illumina BRCA Panel v1.1)

Protocol Type = Library Prep

Next Steps Configuration

Step 1: Clean Up Library (AmpliSeq for Illumina BRCA Panel v1.1)

  • Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

  • Reagent Kits

    • Agencourt AMPure XP Beads

      • Supplier = Thermo

      • Catalog Number = NC9959336; NC9933872

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    70% EtOH Prep Date

    Date

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 2: Amplify Library (AmpliSeq for Illumina BRCA Panel v1.1)

  • Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

  • Reagent Kits

    • Agencourt AMPure XP Beads

      • Supplier = Thermo

      • Catalog Number = NC9959336; NC9933872

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Count Samples and Calculate Master Mix
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \
      -log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'step.::1X Lib AMP Mix (uL):: = step.::Total Samples:: * 1.1 * 45 ; \
step.::10X Library Amp Primers (uL):: = step.::Total Samples:: * 1.1 * 5' \
      -log {compoundOutputFileLuid0}"
Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"
Calculate Total Samples and Calculate Master Mix
  • Trigger Location = Not Used

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \ -t false \ -h false \ -exp 'step.::Total Samples:: = step.::Total Samples:: + 1' \ -log {compoundOutputFileLuid0} && /opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \ script:evaluateDynamicExpression \ -t false \ -h false \ -exp 'step.::1X Lib Amp Mix:: = step.::Total Samples:: * 1.1 * 45 ; \ step.::10X Library Amp Primers:: = step.::Total Samples:: * 1.1 * 5' \ -log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

Group of Defaults

AmpliSeq for CHS V2
  • Thermal Cycler Program = AMP

Equalizer Workflow
  • Thermal Cycler Program = EQUAL

Standard Workflow
  • Thermal Cycler Program = AMP_7

  • Step Data

    • Group of Defaults = Standard Workflow

    • Master Step Fields

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      1X Lib AMP Mix (uL)

      Numeric

      Decimal Places Displayed = 2

      10X Library Amp Primers (uL)

      Numeric

      Decimal Places Displayed = 2

      Thermal Cycler Program

      Text Dropdown

      Custom Entries

      Presets

      • AMP_7

      • EQUAL

      • AMP

      Total Samples

      Numeric

      Default = 0

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 3: Perform Second Clean Up (AmpliSeq for Illumina BRCA Panel v1.1)

  • Master Step Name = Perform Second Clean Up (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • Agencourt AMPure XP Beads

      • Supplier = Thermo

      • Catalog Number = NC9959336; NC9933872

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

bash -l -c "/opt/gls/clarity/bin/java -jar /opt/gls/clarity/extensions/ngs-common/v5/EPP/ngs-extensions.jar -i {stepURI:v2} -u {username} -p {password} \
      script:evaluateDynamicExpression \
      -t false \
      -h false \
      -exp 'nextStep = ::ADVANCE::' \
      -log {compoundOutputFileLuid0}"

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    70% EtOH Prep Date

    Date

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Last updated

Was this helpful?