Clarity LIMS
Illumina Connected Software
Clarity LIMS Software
Clarity LIMS Software
  • Announcements
  • Clarity LIMS
    • Clarity & LabLink
  • API and Database
    • API Portal
      • REST
        • REST General Concepts
        • REST Web Services
        • HTTP Response Codes and Errors
        • XML UTF-8 Character Encoding
        • Requesting API Version Information
        • Viewing Paginated List Resources
        • Filtering List Resources
        • Working with User-Defined Fields (UDF) and Types (UDT)
        • Traversing a Genealogy
        • Working with Batch Resources
      • Getting Started with API
        • Understanding API Terminology (LIMS v5 and later)
        • API-Based URIs (LIMS v4 and later)
        • Development Prerequisites
        • Structure of REST Resources
        • The Life Cycle of a Sample: Stages Versus Steps
        • Integrating Scripts
      • Automation
        • Automation Triggers and Command Line Calls
        • Automation Execution Environment
        • Supported Command Line Interpreters
        • Automation Channels
        • Error Handling
        • Automation Tokens
          • Derived Sample Automation Tokens
          • Step Automation Tokens
          • Project Automation Tokens
        • Automation Testing
        • Troubleshooting Automation
      • Tips and Tricks
        • Accessing Step UDFs from a different Step
        • Obfuscating Sensitive Data in Scripts
        • Integrating Clarity LIMS with Upstream Sample Accessioning Systems
        • Creating Samples and Projects via the API
        • Displaying Files From an Earlier Step
        • Transitioning Output Artifacts into the Next Step
        • Determining the Workflow(s) to Which a Sample is Assigned
        • Standardizing Sample Naming via the API
        • Copying UDF Values from Source to Destination
        • Updating Preset Value of a Step UDF through API
        • Automating BCL Conversion
        • Finding QC Flags in Aggregate QC (Library Validation) via REST API
        • Setting the Value of a QC Flag on an Artifact
        • Creating Notifications When Files are Added via LabLink
        • Remote HTTP Filestore Setup
      • Cookbook
        • Get Started with the Cookbook
          • Tips and Troubleshooting
          • Obtain and Use the REST API Utility Classes
        • Work with EPP/Automation and Files
          • Automation Trigger Configuration
          • Process Execution with EPP/Automation Support
        • Work with Submitted Samples
          • Adding Samples to the System
          • Renaming Samples
          • Assigning Samples to Workflows
          • Updating Sample Information
          • Show the Relationship Between Samples and Analyte Artifacts (Derived Samples)
        • Work with Containers
          • Add an Empty Container to the System
          • Find the Contents of a Well Location in a Container
          • Filter Containers by Name
        • Work with Derived Sample Automations
          • Remove Samples from Workflows
          • Requeue Samples
          • Rearray Samples
        • Work with Process/Step Outputs
          • Update UDF/Custom Field Values for a Derived Sample Output
          • Rename Derived Samples Using the API
          • Find the Container Location of a Derived Sample
          • Traverse a Pooled and Demultiplexed Sample History/Genealogy
          • View the Inputs and Outputs of a Process/Step
        • Work with Projects and Accounts
          • Remove Information from a Project
          • Add a New Project to the System with UDF/Custom Field Value
          • Get a Project Name
          • Find an Account Registered in the System
          • Update Contact (User and Client) Information
        • Work with Multiplexing
          • Find the Index Sequence for a Reagent Label
          • Demultiplexing
          • Pool Samples with Reagent Labels
          • Apply Reagent Labels with REST
          • Apply Reagent Labels When Samples are Imported
          • Apply Reagent Labels by Adding Reagents to Samples
        • Working with User Defined Fields/Custom Fields
          • About UDFs/Custom Fields and UDTs
          • Performing Post-Step Calculations with Custom Fields/UDFs
        • Work with Processes/Steps
          • Filter Processes by Date and Type
          • Find Terminal Processes/Steps
          • Run a Process/Step
          • Update UDF/Custom Field Information for a Process/Step
          • Work with the Steps Pooling Endpoint
        • Work with Batch Resources
          • Introduction to Batch Resources
          • Update UDF/Custom Field Information with Batch Operations
          • Retrieve Multiple Entities with a Single API Interaction
          • Select the Optimal Batch Size
        • Work with Files
          • Attach a File with REST and Python
          • Attach Files Located Outside the Default File Storage Repository
          • Attach a File to a File Placeholder with REST
        • Work with Controls
          • Automated Removal of Controls from a Workflow
      • Application Examples
        • Python API Library (glsapiutil.py) Location
        • Scripts That Help Automate Steps
          • Route Artifacts Based Off a Template File
          • Invoking bcl2fastq from BCL Conversion and Demultiplexing Step
          • Email Notifications
          • Finishing the Current Step and Starting the Next
          • Adding Downstream Samples to Additional Workflows
          • Advancing/Completing a Protocol Step via the API
          • Setting a Default Next Action
          • Automatic Placement of Samples Based on Input Plate Map (Multiple Plates)
          • Automatic Placement of Samples Based on Input Plate Map
          • Publishing Files to LabLink
          • Automatic Pooling Based on a Sample UDF/Custom Field
          • Completing a Step Programmatically
          • Automatic Sample Placement into Existing Containers
          • Routing Output Artifacts to Specific Workflows/Stages
          • Creating Multiple Containers / Types for Placement
          • Starting a Protocol Step via the API
          • Setting Quality Control Flags
          • Applying Indexing Patterns to Containers Automatically
          • Assignment of Sample Next Steps Based On a UDF
          • Parsing Metadata into UDFs (BCL Conversion and Demultiplexing)
        • Scripts That Validate Step Contents
          • Validating Process/Step Level UDFs
          • Checking That Containers Are Named Appropriately
          • Checking for Index Clashes Based on Index Sequence
          • Validating Illumina TruSeq Index Adapter Combinations
        • Scripts Triggered Outside of Workflows/Steps
          • Repurposing a Process to Upload Indexes
          • Adding Users in Bulk
          • Moving Reagent Kits & Lots to New Clarity LIMS Server
          • Programatically Importing the Sample Submission Excel File
          • Generating an MS Excel Sample Submission Spreadsheet
          • Assigning Samples to New Workflows
        • Miscellaneous Scripts
          • Illumina LIMS Integration
          • Generating a Hierarchical Sample History
          • Protocol-based Permissions
          • Self-Incremental Counters
          • Generic CSV Parser Template (Python)
          • Renaming Samples to Add an Internal ID
          • Creating Custom Sample Sheets
          • Copying Output UDFs to Submitted Samples
          • Parsing Sequencing Meta-Data into Clarity LIMS
          • Submit to a Compute Cluster via PBS
          • Downloading a File and PDF Image Extraction
        • Resources and References
          • Understanding LIMS ID Prefixes
          • Container States
          • Useful Tools
          • Unsupported Artifact Types
          • Unsupported Process Types
          • Suggested Reading
          • API Training Videos
  • Illumina Preset Protocols
    • IPP v2.10
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
    • IPP v2.9
      • Release Notes
      • Installation and User Configuration
    • IPP v2.8
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
    • IPP v2.7
      • Release Notes
      • Installation and User Configuration
    • IPP v2.6
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
  • Sample Prep
    • QC and Sample Prep
      • DNA Initial QC 5.1.2
      • RNA Initial QC 5.1.2
      • Library Validation QC 5.1.2
  • Library Prep
    • AmpliSeq for Illumina
      • BRCA Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Cancer HotSpot Panel v2
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Childhood Cancer Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Comprehensive Cancer Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Comprehensive Panel v3
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Custom DNA Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Focus Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Immune Repertoire Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Immune Response Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Myeloid Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • TCR beta-SR Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
      • Transcriptome Human Gene Expression Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
    • Library Prep Validation
    • Nextera
      • Nextera Mate Pair v1.0
      • Nextera Rapid Capture Custom Enrichment v2.0
      • Nextera XT v2.0
    • Targeted Enrichment
      • Illumina DNA Prep with Enrichment (S) Tagmentation v1.2
      • Illumina RNA Prep with Enrichment (L) Tagmentation v1.1
    • TruSeq
      • TruSeq ChIP-Seq v1.0
      • TruSeq Custom Amplicon v1.0
      • TruSeq DNA Exome v2.0
      • TruSeq DNA PCR-Free v2.0
      • TruSeq Methyl Capture EPIC v2.0
      • TruSeq Nano DNA v1.0
      • TruSeq RNA Access v2.0
      • TruSeq RNA Exome v1.0
      • TruSeq Small RNA v1.0
      • TruSeq Stranded mRNA v2.0
    • TruSight
      • TruSight Oncology 500 ctDNA v1.1
      • TruSight Oncology 500 HT v1.1
      • TruSight Oncology 500 v1.1
      • TruSight Tumor 170 v2.0
    • Other DNA Protocols
      • Illumina DNA PCR-Free Library Prep Manual v1.1
      • Illumina DNA Prep (M) Tagmentation v1.0
    • Other RNA Protocols
      • Illumina Stranded mRNA Prep Ligation 1.1
      • Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus v1.1
  • iLASS & Infinium Arrays
    • iLASS
      • iLASS Infinium Genotyping v1.1
        • iLASS Infinium Batch DNA v1.1
        • iLASS Infinium Genotyping Assay v1.1
        • iLASS Infinium Genotyping with PGx Assay v1.1
      • iLASS Infinium Genotyping v1.0
        • iLASS Infinium Genotyping Assay v1.0
        • iLASS Infinium Genotyping with PGx Assay v1.0
    • Infinium Arrays
      • Infinium HD Methylation Assay Manual v1.2
      • Infinium HTS Assay Manual v1.2
      • Infinium LCG Assay Manual v1.2
      • Infinium XT Assay Manual v1.2
      • GenomeStudio v1.0
  • Applications
    • IGA
      • IGA v2.1
        • IGA Library Prep Automated v2.1
        • IGA NovaSeq Sequencing v2.1
    • Viral Pathogen Protocols
      • CDC COVID-19 RT-PCR
        • Sort Specimens to Extraction v1.1
        • Qiagen QIAamp DSP Viral RNA Mini Kit v1.1
        • Qiagen EZ1 Advanced XL v1.1
        • Roche MagNA Pure LC v1.1
        • Roche MagNA Pure Compact v1.1
        • Roche MagNA Pure 96 v1.1
        • bioMerieux NucliSENS easyMAG Instrument v1.1
        • bioMerieux EMAG Instrument v1.1
        • Real-Time RT-PCR Prep v1.1
      • Illumina COVIDSeq v1.6
      • Respiratory Virus Panel v1.0
  • Instruments & Integrations
    • Compatibility
    • Integration Properties
      • Integration Properties Details
    • Clarity LIMS Product Analytics
      • Supported Workflows
      • Workflow Customization
      • Clarity LIMS Product Analytics v1.4.0
        • Configuration
      • Clarity LIMS Product Analytics v1.3.1
        • Configuration
      • Clarity LIMS Product Analytics v1.3.0
        • Configuration
      • Clarity LIMS Product Analytics v1.2.0
        • Configuration
    • Illumina Run Manager
      • Illumina Run Manager v1.0.0
        • Installation and User Interaction
    • iScan
      • iScan System
      • iScan v1.2.0
        • Release Notes
        • BeadChip Accessioning, Imaging, and Analysis
      • iScan v1.1.0
        • Release Notes
        • BeadChip Accessioning, Imaging, and Analysis
      • iScan System v1.0
    • iSeq 100 Run Setup v1.0
    • MiniSeq v1.0
    • MiSeq
      • MiSeq v8.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • MiSeq v8.2.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
    • MiSeq i100 (On-Prem)
      • MiSeq i100 On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • MiSeq i100 (Hosted)
      • MiSeq i100 v1.0.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • MiSeqDx
      • MiSeqDx Sample Sheet Generation (v1.11.0 and later)
      • MiSeqDx v1.11.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • MiSeqDx v1.10.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Sample Sheet Generation
        • Manual Upgrade
    • Next Generation Sequencing Package
      • Release Notes
        • NGS Extensions v5.25.0
        • NGS Extensions v5.24.0
        • NGS Extensions v5.23.0
      • Accession Kit Lots
      • Auto-Placement of Reagent Indexes
      • Compute Replicate Average
      • Copy UDFs
      • Initialize Artifact UDFs
      • Label Non-Labeled Outputs
      • Linear Regression Calculation
      • Normalization Buffer Volumes
      • Process Summary Report
      • Routing Script
      • Set UDF
      • Validate Complete Plate
      • Validate Sample Count
      • Validate Unique Indexes
    • NextSeq 500/550
      • NextSeq 500/550 v2.5.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NextSeq 500/550 v2.4.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NextSeq 500/550 v2.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NextSeq 1000/2000 (Hosted)
      • NextSeq 1000/2000 v2.5.1
        • Release Notes
      • NextSeq 1000/2000 v2.5.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NextSeq 1000/2000 v2.4.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NextSeq 1000/2000 (On-Prem)
      • NextSeq 1000/2000 On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq 6000 (API-based)
      • NovaSeq 6000 API-based v3.7.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000 API-based v3.6.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
    • NovaSeq 6000 (File-based)
      • NovaSeq 6000 File-based v2.6.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000 File-based v2.5.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq 6000Dx (API-based)
      • NovaSeq 6000Dx API-based v1.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000Dx API-based v1.2.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq X Series (Hosted)
      • NovaSeq X Series v1.3.0
        • Release Notes
        • Configuration
        • Manual Upgrade
      • NovaSeq X Series v1.2.1
        • Release Notes
      • NovaSeq X Series v1.2.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NovaSeq X Series v1.1.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq X Series (On-Prem)
      • NovaSeq X Series On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • References
      • Configure Multiple Identical netPathPrefixSearch Values
      • Configure Support for Samples Having Duplicate Names with Different Indexes
      • Illumina Instrument Sample Sheets
      • Terminology
  • Integration Toolkits
    • Lab Instrument Toolkit
      • Template File Generator
        • Creating Template Files
        • Template File Contents
        • Template File Generator Troubleshooting
      • Add Blank Lines
      • Convert CSV to Excel
      • Parse CSV
      • Name Matching XML Parser
      • Sample Placement Helper
    • Lab Logic Toolkit
      • Working with Lab Logic Toolkit
        • Data Collection Entities
        • Failing a Script
        • Mapping Field Types
        • Non-UDF/Custom Field Properties
        • Setting QC Flags
        • Setting Next Actions
        • Specifying Custom Fields
        • Working with Submitted Samples
        • Working with Containers
      • Lab Logic Toolkit Script Examples
        • Comparing Stop/Start Dates and Times with LLTK
      • Lab Logic Toolkit FAQ
  • Known Issues
    • Integration
      • Sample Sheet Generation Issue and CLPA Issues When Samples Have Been Assigned QC Flag Prior to Entering Steps
  • Security Bulletin
    • Investigation of OpenSSH vulnerability with Clarity LIMS
  • Resources
    • Third Party Software Information
  • Others
    • Revision History
Powered by GitBook
On this page
  • Protocols
  • Library Prep Protocols
  • Step 1: Hybridization of Oligo Pool (CF 139-Variant Assay) 1.2
  • Step 2: Removal of Unbound Oligos (CF 139-Variant Assay) 1.2
  • Step 3: Extension-Ligation of Bound Oligos (CF 139-Variant Assay) 1.2
  • Step 4: PCR Amplification (CF 139-Variant Assay) 1.2
  • Step 5: PCR Clean-Up (CF 139-Variant Assay) 1.2
  • MiSeqDx Validation Protocol
  • Activate Workflow, Add and Assign Samples
  • Extension-Ligation of Bound Oligos Step
  • PCR Amplification Step
  • Library Pooling (MiSeqDx) Step
  • Denature, Dilute and Load Sample Step
  • MiSeqDx Run (MiSeqDx) Step
  • Variant Calling (MiSeqDx) Step
  • Illumina SBS MiSeqDx Protocol
  • Sort MiSeqDx Samples (MiSeqDx) Step
  • Library Normalization (MiSeqDx) Step
  • Library Pooling (MiSeqDx) Step
  • Denature, Dilute and Load Sample Step
  • MiSeqDx Run (MiSeqDx) Step
  • Variant Calling (MiSeqDx) Step
  • Validate Creation of Event Files
  • Troubleshooting

Was this helpful?

Export as PDF
  1. Instruments & Integrations
  2. MiSeqDx
  3. MiSeqDx v1.10.0

User Interaction, Validation and Troubleshooting

PreviousConfigurationNextSample Sheet Generation

Last updated 4 months ago

Was this helpful?

This section explains how to use the MiSeqDx Validation workflow that is included in the Illumina MiSeqDx Integration Package. The workflow allows for simple validation of the following functionality:

  • Auto-placement of reagent indexes on the PCR Amplification step

  • Generation of a sample sheet file for use with the MiSeqDx Operating Software (MOS) on the Denature, Dilute and Load Sample step

In addition, this section provides tips to help you troubleshoot the system.

All validation steps assume that you have installed the MiSeqDx Integration Package and have imported the default Clarity LIMS configuration. The validation steps are based on MiSeqDx Validation (CF 139-Variant Assay) 1.2, where the autoplacement of indexes validation occurs in Run PCR Amplification step and sample sheet generation validation occurs in Run Denature, Dilute and Load Samples step.

For compatibility information, refer to . Only Clarity LIMS v6.2 or later is supported in MiSeqDx Integration Package v1.10.0 or in subsequent releases.

Instructions for configuring sample sheet generation are provided in .

Protocols

The following protocols are included in MiSeqDx Integration Package v1.10.0.

  • Library Prep Protocols:

    • CF 139-Variant Assay Library Prep 1.2

    • CF Clinical Sequencing Assay Library Prep 1.2

    • Universal Kit Library Prep 1.2

  • Illumina SBS MiSeqDx Protocols:

    • Illumina SBS MiSeqDx (CF 139-Variant Assay) 1.2

    • Illumina SBS MiSeqDx (CF Clinical Sequencing Assay) 1.2

    • Illumina SBS MiSeqDx (Universal Kit) 1.2

  • Validation Protocols:

    • MiSeqDx Validation (CF 139-Variant Assay) 1.2

    • MiSeqDx Validation (CF Clinical Sequencing Assay) 1.2

    • MiSeqDx Validation (Universal Kit) 1.2

Each validation protocol includes the following steps from the Library Prep and Illumina SBS MiSeqDx protocols:

  • Extension-Ligation of Bound Oligos (Library Prep step)

  • PCR Amplification (Library Prep step)

  • Library Pooling (MiSeqDx) (Illumina SBS MiSeqDx step)

  • Denature, Dilute and Load Sample (Illumina SBS MiSeqDx step)

  • MiSeqDx Run (MiSeqDx) (Illumina SBS MiSeqDx step)

  • Variant Calling (MiSeqDx) (Illumina SBS MiSeqDx step)

Library Prep Protocols

This section discusses the Library Prep protocols included in the MiSeqDx v1.10.0 Integration Package.

Step 1: Hybridization of Oligo Pool (CF 139-Variant Assay) 1.2

The following process is used to hybridize the oligo pool.

  1. Add samples to Ice Bucket.

  2. Add Negative Control and Positive Control samples to Ice Bucket.

    ℹ Good laboratory practices mandate that a positive control DNA sample and a negative (no-template) control sample are included in every run. The positive control DNA sample should be a well-characterized sample with a known CFTR mutation.

  3. Select Begin Work.

  4. On the Placement screen, select all samples and place in container. Select Record Details.

  5. On the Record Details screen, under Reagent Lot Tracking, set the following values:

    • gDNA Concentration (ng/uL): 50 ng/ul

    • gDNA Volume (uL): 5 uL

    • Select the reagent lots for CF 139-Variant Assay-Oligo Pool and Hybridization Buffer.

  6. Select Next Steps.

  7. Select Removal of Unbound Oligos (CF 139-Variant Assay) 1.2 as the next step.

  8. Select Apply.

  9. Select Finish Step.

Step 2: Removal of Unbound Oligos (CF 139-Variant Assay) 1.2

The process below is used to remove unbound oligos.

  1. Add samples to Ice Bucket.

  2. Select Begin Work.

  3. On the Placement screen, select all samples and place in container.

  4. Select Record Details.

  5. On the Record Details screen, under Reagent Lot Tracking, select the reagent lots for Stringent Wash Buffer and Universal Wash Buffer.

  6. Select Next Steps.

  7. Select Extension-Ligation of Bound Oligos (CF 139-Variant Assay) 1.2 as the next step.

  8. Select Apply.

  9. Select Finish Step.

Step 3: Extension-Ligation of Bound Oligos (CF 139-Variant Assay) 1.2

The process below is used to add reagents to the Extension-Ligation Mix field.

  1. Add samples to Ice Bucket. Select Begin Work.

  2. On the Placement screen, select all samples and place in container.

  3. Select Record Details.

  4. On the Record Details screen, under Reagent Lot Tracking, select the reagent lots for Extension-Ligation Mix.

  5. Select Next Steps.

  6. Select PCR Amplification (CF 139-Variant Assay) 1.2 as the next step.

  7. Select Apply.

  8. Select Finish Step.

Step 4: PCR Amplification (CF 139-Variant Assay) 1.2

  1. Add samples to Ice Bucket.

  2. Select one of the following Reagent Label Options:

    • If you are working with eight samples or less, select CF 139-Variant Assay 8-Sample Indexes.

    • If you are working with more than 8 samples, select CF 139-Variant Assay Indexes.

  3. Select Begin Work.

  4. On the Placement screen, select all samples and place in container. Select Add Reagents.

    On entry to the Add Reagents screen, the Auto Place Indexes automation is invoked and the reagents are placed on the samples.

  5. Once placement is complete, a message displays indicating that the index pattern has been applied successfully. Select OK.

  6. On Add Reagents screen, reagents are already placed. Select Record Details.

  7. On exit from the Add Reagents screen, the index placement is validated. Once validation is complete, a message displays indicating that the index pattern has been validated on all samples successfully. Select OK.

  8. On the Record Details screen, under Reagent Lot Tracking, enter the lots for the following fields:

    • Index Primers

    • NaOH

    • PCR Master Mix

    • PCR Polymerase

  9. Select Next Steps.

  10. Select PCR Clean-Up (CF 139-Variant Assay) 1.2 as the next step.

  11. Select Apply.

  12. Select Finish Step.

Step 5: PCR Clean-Up (CF 139-Variant Assay) 1.2

  1. Add samples to Ice Bucket.

  2. Select Begin Work.

  3. On the Placement screen, select all samples and place in container. Select Record Details.

  4. On the Record Details screen, under Reagent Lot Tracking, select the reagent lots for the following:

    • Elution Buffer

    • EtOH

    • PCR Clean-up Beads

  5. Select Next Steps.

  6. Select Mark protocol as complete as the next step. Select Apply.

  7. Select Finish Step.

MiSeqDx Validation Protocol

Follow the following steps to validate auto-placement of indexes and sample sheet generation

Activate Workflow, Add and Assign Samples

  1. In the Clarity LIMS web interface, on the Configuration > Workflows screen, activate one of the three Validation workflows:

    • MiSeqDx Validation (CF 139-Variant Assay) 1.2

    • MiSeqDx Validation (CF Clinical Sequencing Assay) 1.2

    • MiSeqDx Validation (Universal Kit) 1.2

    ℹ The validation steps are based on MiSeqDx Validation (CF 139-Variant Assay) 1.2

  2. On the Projects and Samples screen, create a project and assign samples as follows.

    1. Create a test project and add samples to it.

      âš  The project must contain between 9 and 96 samples.

    2. Assign your samples to the MiSeqDx Validation workflow.

Extension-Ligation of Bound Oligos Step

  1. In Lab View, locate the MiSeqDx Validation protocol. You will see your samples queued for the Extension-Ligation of Bound Oligos step. Prepare the samples as follows.

  2. Add the samples to the Ice Bucket.

  3. On the Placement screen, place the samples into the output container.

  4. Select Record Details.

  5. On the Record Details screen, under Reagent Lot Tracking, select the Extension-Ligation Mix reagent lot used in the step.

    If required, activate the lot on the Reagents / Reagents and Controls screen.

  6. Select Next Steps.

  7. On the Assign Next Steps screen, assign the samples to the PCR Amplification step.

  8. Select Finish Step.

PCR Amplification Step

  1. In Lab View, locate the MiSeqDx Validation protocol. You will see your samples queued for the PCR Amplification step.

  2. Add the samples to the Ice Bucket.

  3. In the Reagent Label Options panel, in the Group of labels list, select CF 139-Variant Assay Indexes (or the equivalent for the workflow you activated).

  4. Select Begin Work.

  5. On the Placement screen, place the samples into the output container.

  6. Select Add Reagents.

    On entry to the Add Reagents screen, the Auto Place Indexes automation is automatically invoked and the reagents are placed on the samples.

  7. After placement is complete, a message displays indicating that the index pattern has been applied successfully. Select OK.

  8. On the Add Reagents screen, reagents are already placed. Select Record Details.

    On exit from the Add Reagents screen, the Validate Index Placement automation is automatically invoked and index placement is validated.

  9. When validation is complete, a message displays indicating that the index pattern has been validated on all samples successfully. Select OK.

  10. On the Record Details screen, under Reagent Lot Tracking, select the lots for the following items:

    • Index Primers

    • NaOH

    • PCR Master Mix

    • PCR Polymerase

  11. Select Next Steps.

  12. On the Assign Next Steps screen, assign samples to the Library Pooling (MiSeqDx) 1.2 step.

  13. Select Finish Step.

Library Pooling (MiSeqDx) Step

  1. Return to Lab View and locate the MiSeqDx Validation protocol. You will see your samples queued for the Library Pooling (MiSeqDx) 1.2 step.

    Prepare the samples as follows.

  2. Add samples to the Ice Bucket.

  3. In the Add Control Samples panel, select PhiX Internal Control. Select Begin Work.

  4. On the Pool Samples screen, create a pool of samples. Select Place Samples.

  5. On the Placement screen, place the pool into the output container. Select Record Details.

  6. Under Reagent Lot Tracking, select the reagent lot used in the step.

  7. Under Step Details, enter the concentration value in the Normalized conc. (nM) field.

  8. Select Next Steps.

  9. On the Assign Next Steps screen, assign the pool to the Denature, Dilute and Load Samples step.

Denature, Dilute and Load Sample Step

  1. Return to Lab View and locate the MiSeqDx Validation protocol.

    You will see your pooled samples queued for the Denature, Dilute and Load Sample step.

  2. Place the pooled samples as follows.

    1. Add the pool to the Ice Bucket.

      On the Place Samples screen, the Validate Single Input script runs and validates only one pool that is entered into this step as the input sample. If validation fails, Clarity LIMS prompts you that it is only able to proceed with the step with one pool.

    2. On the Placement screen, place the pool into a MiSeqDx reagent cartridge.

    3. Select Record Details.

      On entry to the Record Details screen, a script validates the Container Name and prompts you to scan the reagent cartridge barcode.

  3. On the Record Details screen of the Denature, Dilute and Load Sample step, generate the sample sheet as follows.

    ℹ All read-only files are autopopulated.

    1. Enter the folder path for the Reference Genomes that will be used for secondary analysis in the GenomeFolder field.

    2. Under Reagent Lot Tracking, select the reagent lots used in the step.

    3. Enter the lots for MiSeqDx Flow Cell - CF 139-Variant Assay and MiSeqDx SBS Solution (PR2) - CF 139-Variant Assay.

    4. In the Step Details section, review the step parameters.

    5. Select Generate MiSeqDx Sample Sheet to generate the MiSeqDx sample sheet.

    6. Clarity LIMS attaches the generated sample sheet and log file to placeholders in the Files area of the Record Details screen. Download the files and validate their format and content.

    7. [Optional] In the Files section, upload the Lab Tracking Form to the appropriate placeholder.

  4. Select Next Steps.

  5. On the Assign Next Steps screen, assign the samples to the MiSeqDx Run (MiSeqDx) 1.2 step.

Validation of auto-placement of indexes and sample sheet generation is completed at the end of this step.

MiSeqDx Run (MiSeqDx) Step

On the Record Details screen, do not select the AUTOMATED - Run Report Generation button. The run report is generated and attached to the step automatically. This process may take a while.

On the Record Details screen of the MiSeqDx Run (MiSeqDx) 1.2 step:

  1. Run the instrument. The read-only field values are automatically populated as the instrument runs.

  2. After the run has completed, observe the Record Details screen of the MiSeqDx Run (MiSeqDx) 1.2 step for the following.

    • The autopopulated read-only fields.

    • The generated and attached Illumina Run Report and Log File.

    • The attached Run Parameters and Run Info files.

    • The generated and attached Link to Run Folder.

    • QC flags set on each lane.

  3. [Optional] In the Files section, upload the Lab Tracking Form.

  4. Select Next Steps.

    The Verify Report Status automation should run and allow you to go to the Assign Next Steps screen.

  5. On the Assign Next Steps screen, assign the samples to the Variant Calling (MiSeqDx) 1.2 step.

  6. Select Finish Step.

Variant Calling (MiSeqDx) Step

On the Record Details screen of the Variant Calling (MiSeqDx) 1.2 step:

  1. Make sure that the VCF has the correct name based on the sample sheet.

    The file-naming format for the VCF file is SampleName_S#.vcf. In this format, the SampleName is the value in the Sample_Name column of the sample sheet, and # is the sample number determined by the order in which samples are listed in the sample sheet.

  2. After secondary analysis has completed, the following files are attached to the step:

    • Combined Variant Call File — a compressed VCF file (zip file) containing all the variant call files, including the CFTR specific VCF files.

    • Combined Output Text File — a combined text file containing a summary of all the sample metrics.

    • Variant Call File per individual sample

  3. QC flags are set on each lane.

Illumina SBS MiSeqDx Protocol

Sort MiSeqDx Samples (MiSeqDx) Step

This step routes your samples to the appropriate next step. Assign each sample to one of the following steps:

  • Library Normalization (MiSeqDx)

  • Library Pooling (MiSeqDx)

  • Denature, Dilute and Load Sample

Library Normalization (MiSeqDx) Step

  1. On the Record Details screen, enter values for the following items:

    • Library volume (µl) transferred to destination plate

    • Normalized conc (nM)

    • Maximum destination container volume (µl)

    • Any other required fields

  2. Select Create Normalization CSV to start the automation.

    When the normalizationBufferVolumes script has completed, the Normalization buffer volumes CSV file is generated and attached to the step. This file is in the Files area of the Record Details screen.

Library Pooling (MiSeqDx) Step

Denature, Dilute and Load Sample Step

  1. On the Placement screen, set up the reagent cartridge as follows.

    1. Using an RFID scanner, scan the RFID of the MiSeqDx reagent cartridge into the Container Name field.

    2. Place the pool of samples into the reagent cartridge.

  2. Select Record Details.

On exit from the Placement screen, the automation is automatically triggered and validates the Container Name.

MiSeqDx Run (MiSeqDx) Step

Variant Calling (MiSeqDx) Step

Validate Creation of Event Files

Validating the creation of the event files confirms the following:

  • Your DESTINATION_PATH is correctly configured.

  • The instrument computer can access and write to the DESTINATION_PATH.

  • There are no syntax errors in the Clarity LIMS batch file.

Follow the steps below to confirm that event files are created by the batch file in the destination path. The steps assume that the default configuration has been successfully imported.

  1. In C:\Illumina\gls, double-click gls_event_mos_rta.bat.

  2. Confirm that an empty event file appears in the configured DESTINATION_PATH.

  3. Manually invoke the gls_event_mos.bat file.

    The file produces an output similar to the following example:

    cycleNumber = 318
    runFolder = "D:\Illumina\MiSeqTemp\161030_M99999_0056_FC1234567-ABCDE"
    netFolder = "D:\Illumina\MiSeqOutput\161030_M99999_0056_FC1234567-ABCDE"
    readType = 4
    eventType = EndRun
    softwareType = MOS
    finishDate = 2016-10-30

Troubleshooting

If an automation trigger does not appear to run its corresponding scripts, see:

If an error occurs that does not provide direction on how to proceed, troubleshoot the error as follows.

  1. Confirm the version of the installed Illumina MiSeqDx Integration Package by running the following command from the server console.

    rpm -qa | grep -i miseqdx
  2. If the error is related to retrieving run results data, review the MiseqDxIntegrator.log.

  3. Contact the Clarity LIMS Support team, supplying the relevant information from the troubleshooting already performed.

Refer to under MiSeqDx Validation Protocol for details.

Refer to under MiSeqDx Validation Protocol for more details.

Refer to under MiSeqDx Validation Protocol for details.

Refer to under MiSeqDx Validation Protocol for details.

Troubleshooting Automation Worker in the .

Troubleshooting Automation in the .

MiSeqDx Integration v1.10.0 Release Notes
MiSeqDx Integration v1.10.0 Configuration
Clarity LIMS (Clarity & LabLink Reference Guide) documentation
Clarity LIMS (API & Database) documentation
Library Pooling (MiSeqDx) step
Denature, Diluate and Load Sample step
MiSeqDx Run (MiSeqDx) step
Variant Calling (MiSeqDx) step