Standard v1.1
Last updated
Last updated
The Standard Workflow AmpliSeq for Illumina Myeloid Panel is part of the AmpliSeq for Illumina Myeloid Panel protocols which include the following functionality:
Preconfigured AmpliSeq for Illumina Myeloid Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of genomic DNA or total RNA using the AmpliSeq for Illumina workflow.
Automated calculation of sample and buffer volumes.
Automated calculation or display of reagents at every step in the protocol.
Automatic step transition when required.Automatic placement of samples when necessary.
Automated assignment of QC Pass/Fail, based on user-selected threshold values.
There is no extraction protocol in this workflow because the samples are already extracted.
Protocol Type = Library Prep
Next Steps Configuration
Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)
Step Type = No Outputs
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields
Master Step Name = Perform Second Clean Up (AmpliSeq for Illumina v1.1)
Step Type = Standard
Derived Sample Generation = Fixed, 1
Naming Convention = {InputItemName}
Reagent Kits
Agencourt AMPure XP Beads
Supplier = Thermo
Catalog Number = NC9959336; NC9933872
AmpliSeq Library PLUS for Illumina
Supplier = Illumina
Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103
Website = www.illumina.com
Defaults
Sample Grouping = Group by Containers
Well Sort Order = Row
Sample Table (Column Headers)
Step Data (Master Step Fields)
Step File Placeholders
Log - Automatically attached
Sample Table
Sample Display Default = Expand
Well Sort Order = Row
Table Columns - Global Fields