Clarity LIMS
Illumina Connected Software
Clarity LIMS Software
Clarity LIMS Software
  • Announcements
  • Clarity LIMS
    • Clarity & LabLink
  • API and Database
    • API Portal
      • REST
        • REST General Concepts
        • REST Web Services
        • HTTP Response Codes and Errors
        • XML UTF-8 Character Encoding
        • Requesting API Version Information
        • Viewing Paginated List Resources
        • Filtering List Resources
        • Working with User-Defined Fields (UDF) and Types (UDT)
        • Traversing a Genealogy
        • Working with Batch Resources
      • Getting Started with API
        • Understanding API Terminology (LIMS v5 and later)
        • API-Based URIs (LIMS v4 and later)
        • Development Prerequisites
        • Structure of REST Resources
        • The Life Cycle of a Sample: Stages Versus Steps
        • Integrating Scripts
      • Automation
        • Automation Triggers and Command Line Calls
        • Automation Execution Environment
        • Supported Command Line Interpreters
        • Automation Channels
        • Error Handling
        • Automation Tokens
          • Derived Sample Automation Tokens
          • Step Automation Tokens
          • Project Automation Tokens
        • Automation Testing
        • Troubleshooting Automation
      • Tips and Tricks
        • Accessing Step UDFs from a different Step
        • Obfuscating Sensitive Data in Scripts
        • Integrating Clarity LIMS with Upstream Sample Accessioning Systems
        • Creating Samples and Projects via the API
        • Displaying Files From an Earlier Step
        • Transitioning Output Artifacts into the Next Step
        • Determining the Workflow(s) to Which a Sample is Assigned
        • Standardizing Sample Naming via the API
        • Copying UDF Values from Source to Destination
        • Updating Preset Value of a Step UDF through API
        • Automating BCL Conversion
        • Finding QC Flags in Aggregate QC (Library Validation) via REST API
        • Setting the Value of a QC Flag on an Artifact
        • Creating Notifications When Files are Added via LabLink
        • Remote HTTP Filestore Setup
      • Cookbook
        • Get Started with the Cookbook
          • Tips and Troubleshooting
          • Obtain and Use the REST API Utility Classes
        • Work with EPP/Automation and Files
          • Automation Trigger Configuration
          • Process Execution with EPP/Automation Support
        • Work with Submitted Samples
          • Adding Samples to the System
          • Renaming Samples
          • Assigning Samples to Workflows
          • Updating Sample Information
          • Show the Relationship Between Samples and Analyte Artifacts (Derived Samples)
        • Work with Containers
          • Add an Empty Container to the System
          • Find the Contents of a Well Location in a Container
          • Filter Containers by Name
        • Work with Derived Sample Automations
          • Remove Samples from Workflows
          • Requeue Samples
          • Rearray Samples
        • Work with Process/Step Outputs
          • Update UDF/Custom Field Values for a Derived Sample Output
          • Rename Derived Samples Using the API
          • Find the Container Location of a Derived Sample
          • Traverse a Pooled and Demultiplexed Sample History/Genealogy
          • View the Inputs and Outputs of a Process/Step
        • Work with Projects and Accounts
          • Remove Information from a Project
          • Add a New Project to the System with UDF/Custom Field Value
          • Get a Project Name
          • Find an Account Registered in the System
          • Update Contact (User and Client) Information
        • Work with Multiplexing
          • Find the Index Sequence for a Reagent Label
          • Demultiplexing
          • Pool Samples with Reagent Labels
          • Apply Reagent Labels with REST
          • Apply Reagent Labels When Samples are Imported
          • Apply Reagent Labels by Adding Reagents to Samples
        • Working with User Defined Fields/Custom Fields
          • About UDFs/Custom Fields and UDTs
          • Performing Post-Step Calculations with Custom Fields/UDFs
        • Work with Processes/Steps
          • Filter Processes by Date and Type
          • Find Terminal Processes/Steps
          • Run a Process/Step
          • Update UDF/Custom Field Information for a Process/Step
          • Work with the Steps Pooling Endpoint
        • Work with Batch Resources
          • Introduction to Batch Resources
          • Update UDF/Custom Field Information with Batch Operations
          • Retrieve Multiple Entities with a Single API Interaction
          • Select the Optimal Batch Size
        • Work with Files
          • Attach a File with REST and Python
          • Attach Files Located Outside the Default File Storage Repository
          • Attach a File to a File Placeholder with REST
        • Work with Controls
          • Automated Removal of Controls from a Workflow
      • Application Examples
        • Python API Library (glsapiutil.py) Location
        • Scripts That Help Automate Steps
          • Route Artifacts Based Off a Template File
          • Invoking bcl2fastq from BCL Conversion and Demultiplexing Step
          • Email Notifications
          • Finishing the Current Step and Starting the Next
          • Adding Downstream Samples to Additional Workflows
          • Advancing/Completing a Protocol Step via the API
          • Setting a Default Next Action
          • Automatic Placement of Samples Based on Input Plate Map (Multiple Plates)
          • Automatic Placement of Samples Based on Input Plate Map
          • Publishing Files to LabLink
          • Automatic Pooling Based on a Sample UDF/Custom Field
          • Completing a Step Programmatically
          • Automatic Sample Placement into Existing Containers
          • Routing Output Artifacts to Specific Workflows/Stages
          • Creating Multiple Containers / Types for Placement
          • Starting a Protocol Step via the API
          • Setting Quality Control Flags
          • Applying Indexing Patterns to Containers Automatically
          • Assignment of Sample Next Steps Based On a UDF
          • Parsing Metadata into UDFs (BCL Conversion and Demultiplexing)
        • Scripts That Validate Step Contents
          • Validating Process/Step Level UDFs
          • Checking That Containers Are Named Appropriately
          • Checking for Index Clashes Based on Index Sequence
          • Validating Illumina TruSeq Index Adapter Combinations
        • Scripts Triggered Outside of Workflows/Steps
          • Repurposing a Process to Upload Indexes
          • Adding Users in Bulk
          • Moving Reagent Kits & Lots to New Clarity LIMS Server
          • Programatically Importing the Sample Submission Excel File
          • Generating an MS Excel Sample Submission Spreadsheet
          • Assigning Samples to New Workflows
        • Miscellaneous Scripts
          • Illumina LIMS Integration
          • Generating a Hierarchical Sample History
          • Protocol-based Permissions
          • Self-Incremental Counters
          • Generic CSV Parser Template (Python)
          • Renaming Samples to Add an Internal ID
          • Creating Custom Sample Sheets
          • Copying Output UDFs to Submitted Samples
          • Parsing Sequencing Meta-Data into Clarity LIMS
          • Submit to a Compute Cluster via PBS
          • Downloading a File and PDF Image Extraction
        • Resources and References
          • Understanding LIMS ID Prefixes
          • Container States
          • Useful Tools
          • Unsupported Artifact Types
          • Unsupported Process Types
          • Suggested Reading
          • API Training Videos
  • Illumina Preset Protocols
    • IPP v2.10
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
    • IPP v2.9
      • Release Notes
      • Installation and User Configuration
    • IPP v2.8
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
    • IPP v2.7
      • Release Notes
      • Installation and User Configuration
    • IPP v2.6
      • Release Notes
      • Installation and User Configuration
      • Manual Upgrade
  • Sample Prep
    • QC and Sample Prep
      • DNA Initial QC 5.1.2
      • RNA Initial QC 5.1.2
      • Library Validation QC 5.1.2
  • Library Prep
    • AmpliSeq for Illumina
      • BRCA Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Cancer HotSpot Panel v2
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Childhood Cancer Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Comprehensive Cancer Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Comprehensive Panel v3
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Custom DNA Panel
        • Library Preparation v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Focus Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Immune Repertoire Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Immune Response Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • Myeloid Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
      • TCR beta-SR Panel
        • DNA Library Prep v1.1
        • RNA Library Prep v1.1
      • Transcriptome Human Gene Expression Panel
        • RNA Library Prep v1.1
        • Equalizer v1.1
        • Standard v1.1
    • Library Prep Validation
    • Nextera
      • Nextera Mate Pair v1.0
      • Nextera Rapid Capture Custom Enrichment v2.0
      • Nextera XT v2.0
    • Targeted Enrichment
      • Illumina DNA Prep with Enrichment (S) Tagmentation v1.2
      • Illumina RNA Prep with Enrichment (L) Tagmentation v1.1
    • TruSeq
      • TruSeq ChIP-Seq v1.0
      • TruSeq Custom Amplicon v1.0
      • TruSeq DNA Exome v2.0
      • TruSeq DNA PCR-Free v2.0
      • TruSeq Methyl Capture EPIC v2.0
      • TruSeq Nano DNA v1.0
      • TruSeq RNA Access v2.0
      • TruSeq RNA Exome v1.0
      • TruSeq Small RNA v1.0
      • TruSeq Stranded mRNA v2.0
    • TruSight
      • TruSight Oncology 500 ctDNA v1.1
      • TruSight Oncology 500 HT v1.1
      • TruSight Oncology 500 v1.1
      • TruSight Tumor 170 v2.0
    • Other DNA Protocols
      • Illumina DNA PCR-Free Library Prep Manual v1.1
      • Illumina DNA Prep (M) Tagmentation v1.0
    • Other RNA Protocols
      • Illumina Stranded mRNA Prep Ligation 1.1
      • Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus v1.1
  • iLASS & Infinium Arrays
    • iLASS
      • iLASS Infinium Genotyping v1.1
        • iLASS Infinium Batch DNA v1.1
        • iLASS Infinium Genotyping Assay v1.1
        • iLASS Infinium Genotyping with PGx Assay v1.1
      • iLASS Infinium Genotyping v1.0
        • iLASS Infinium Genotyping Assay v1.0
        • iLASS Infinium Genotyping with PGx Assay v1.0
    • Infinium Arrays
      • Infinium HD Methylation Assay Manual v1.2
      • Infinium HTS Assay Manual v1.2
      • Infinium LCG Assay Manual v1.2
      • Infinium XT Assay Manual v1.2
      • GenomeStudio v1.0
  • Applications
    • IGA
      • IGA v2.1
        • IGA Library Prep Automated v2.1
        • IGA NovaSeq Sequencing v2.1
    • Viral Pathogen Protocols
      • CDC COVID-19 RT-PCR
        • Sort Specimens to Extraction v1.1
        • Qiagen QIAamp DSP Viral RNA Mini Kit v1.1
        • Qiagen EZ1 Advanced XL v1.1
        • Roche MagNA Pure LC v1.1
        • Roche MagNA Pure Compact v1.1
        • Roche MagNA Pure 96 v1.1
        • bioMerieux NucliSENS easyMAG Instrument v1.1
        • bioMerieux EMAG Instrument v1.1
        • Real-Time RT-PCR Prep v1.1
      • Illumina COVIDSeq v1.6
      • Respiratory Virus Panel v1.0
  • Instruments & Integrations
    • Compatibility
    • Integration Properties
      • Integration Properties Details
    • Clarity LIMS Product Analytics
      • Supported Workflows
      • Workflow Customization
      • Clarity LIMS Product Analytics v1.4.0
        • Configuration
      • Clarity LIMS Product Analytics v1.3.1
        • Configuration
      • Clarity LIMS Product Analytics v1.3.0
        • Configuration
      • Clarity LIMS Product Analytics v1.2.0
        • Configuration
    • Illumina Run Manager
      • Illumina Run Manager v1.0.0
        • Installation and User Interaction
    • iScan
      • iScan System
      • iScan v1.2.0
        • Release Notes
        • BeadChip Accessioning, Imaging, and Analysis
      • iScan v1.1.0
        • Release Notes
        • BeadChip Accessioning, Imaging, and Analysis
      • iScan System v1.0
    • iSeq 100 Run Setup v1.0
    • MiniSeq v1.0
    • MiSeq
      • MiSeq v8.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • MiSeq v8.2.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
    • MiSeq i100 (On-Prem)
      • MiSeq i100 On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • MiSeq i100 (Hosted)
      • MiSeq i100 v1.0.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • MiSeqDx
      • MiSeqDx Sample Sheet Generation (v1.11.0 and later)
      • MiSeqDx v1.11.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • MiSeqDx v1.10.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Sample Sheet Generation
        • Manual Upgrade
    • Next Generation Sequencing Package
      • Release Notes
        • NGS Extensions v5.25.0
        • NGS Extensions v5.24.0
        • NGS Extensions v5.23.0
      • Accession Kit Lots
      • Auto-Placement of Reagent Indexes
      • Compute Replicate Average
      • Copy UDFs
      • Initialize Artifact UDFs
      • Label Non-Labeled Outputs
      • Linear Regression Calculation
      • Normalization Buffer Volumes
      • Process Summary Report
      • Routing Script
      • Set UDF
      • Validate Complete Plate
      • Validate Sample Count
      • Validate Unique Indexes
    • NextSeq 500/550
      • NextSeq 500/550 v2.5.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NextSeq 500/550 v2.4.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NextSeq 500/550 v2.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NextSeq 1000/2000 (Hosted)
      • NextSeq 1000/2000 v2.5.1
        • Release Notes
      • NextSeq 1000/2000 v2.5.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NextSeq 1000/2000 v2.4.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NextSeq 1000/2000 (On-Prem)
      • NextSeq 1000/2000 On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq 6000 (API-based)
      • NovaSeq 6000 API-based v3.7.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000 API-based v3.6.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
    • NovaSeq 6000 (File-based)
      • NovaSeq 6000 File-based v2.6.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000 File-based v2.5.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq 6000Dx (API-based)
      • NovaSeq 6000Dx API-based v1.3.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
      • NovaSeq 6000Dx API-based v1.2.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq X Series (Hosted)
      • NovaSeq X Series v1.3.0
        • Release Notes
        • Configuration
        • Manual Upgrade
      • NovaSeq X Series v1.2.1
        • Release Notes
      • NovaSeq X Series v1.2.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
        • Manual Upgrade
      • NovaSeq X Series v1.1.0
        • Release Notes
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • NovaSeq X Series (On-Prem)
      • NovaSeq X Series On-Prem v1.0.0
        • Release Notes
        • Installation
        • Configuration
        • User Interaction, Validation and Troubleshooting
    • References
      • Configure Multiple Identical netPathPrefixSearch Values
      • Configure Support for Samples Having Duplicate Names with Different Indexes
      • Illumina Instrument Sample Sheets
      • Terminology
  • Integration Toolkits
    • Lab Instrument Toolkit
      • Template File Generator
        • Creating Template Files
        • Template File Contents
        • Template File Generator Troubleshooting
      • Add Blank Lines
      • Convert CSV to Excel
      • Parse CSV
      • Name Matching XML Parser
      • Sample Placement Helper
    • Lab Logic Toolkit
      • Working with Lab Logic Toolkit
        • Data Collection Entities
        • Failing a Script
        • Mapping Field Types
        • Non-UDF/Custom Field Properties
        • Setting QC Flags
        • Setting Next Actions
        • Specifying Custom Fields
        • Working with Submitted Samples
        • Working with Containers
      • Lab Logic Toolkit Script Examples
        • Comparing Stop/Start Dates and Times with LLTK
      • Lab Logic Toolkit FAQ
  • Known Issues
    • Integration
      • Sample Sheet Generation Issue and CLPA Issues When Samples Have Been Assigned QC Flag Prior to Entering Steps
  • Security Bulletin
    • Investigation of OpenSSH vulnerability with Clarity LIMS
  • Resources
    • Third Party Software Information
  • Others
    • Revision History
Powered by GitBook
On this page
  • Analysis Configuration Template Creation in BaseSpace Sequence Hub
  • Activate Workflow, Create Project, Add and Assign Samples
  • Library Prep Protocol
  • Protocol: NovaSeq X Series Sequencing v1.0
  • Step 1: Assign Analysis Configuration Template (NovaSeq X Series Sequencing v1.0)
  • Step 2: Make Bulk Pool (NovaSeq X Series Sequencing v1.0)
  • Step 3: Dilute and Denature (NovaSeq X Series Sequencing v1.0)
  • Step 4: Load to Library Tube Strip (NovaSeq X Series Sequencing v1.0)
  • Step 5: AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0)
  • Troubleshooting
  • Automated Step Does Not Start
  • Automated Step Starts, But Does Not Complete
  • Validate Analysis Configuration Automation Check Fails
  • Revision History

Was this helpful?

Export as PDF
  1. Instruments & Integrations
  2. NovaSeq X Series (Hosted)
  3. NovaSeq X Series v1.1.0

User Interaction, Validation and Troubleshooting

PreviousConfigurationNextNovaSeq X Series (On-Prem)

Last updated 4 months ago

Was this helpful?

Last Updated: December 2024

Release Date: September 2023

Document Version: 2

This section explains the user interaction for each step and how to validate the installation of the Illumina NovaSeq X Series Integration Package v1.1.0.

The validation process involves the following actions:

  • Running samples through the Library Prep Validation v2.3.1 workflow.

    • The workflow contains a single-step protocol that models the library prep required to produce libraries tagged with index sequences. At the end of the step, these libraries are routed to NovaSeq X Series Sequencing v1.0 workflow.

  • Running libraries through the NovaSeq X Series Sequencing v1.0 workflow validates the following items:

    • Successful sequential step advancement of samples through the steps of the workflow.

    • Automatic validation of run setup information before sample sheet generation or planned run creation.

    • Automated sample sheet generation. This sample sheet is used to start the sequencing run on the NovaSeq X Series Control Software through the Local run mode.

    • Automated creation of a planned run in Illumina Connected Analytics (ICA). The control software retrieves the planned run. The run is started through the Cloud run mode.

    • Automated tracking of the NovaSeq X Series sequencing run and parsing of run statistics into Clarity LIMS.

The validation steps assume that the following conditions have been met:

  • NovaSeq X Series Integration Package v1.1.0 is installed and you have imported the default Clarity LIMS configuration.

  • Analysis configuration templates (ACTs) are created in BaseSpace Sequence Hub for your run. Make sure that the index adapter kit label group is created in Clarity LIMS before selecting it in the ACT. This same label group is used in the Run Library Prep Validation v2.3.1 step. For more information on creating a reagent label group, refer to Add and Configure Labels and Label Groups in the . For the adapter sequences for your library prep kits, refer to .

Analysis Configuration Template Creation in BaseSpace Sequence Hub

Activate Workflow, Create Project, Add and Assign Samples

The following steps set up Clarity LIMS in preparation for running samples through the Library Prep Validation v2.3.1 and NovaSeq X Series Sequencing v1.0 workflows.

  1. On the Configuration tab, under Workflows, activate both the Library Prep Validation v2.3.1 and NovaSeq X Series Sequencing v1.0 workflows.

  2. On the Projects and Samples screen, create a project and add samples to it.

    âš  Only use alphanumeric, dash, or underscore characters in the submitted sample names. Invalid characters can cause a sample sheet validation failure in the Load to Library Tube Strip step.

  3. Assign the samples to the Library Prep Validation workflow.

Library Prep Protocol

This single-step protocol models the library prep required to produce libraries tagged with index sequences that are ready for the NovaSeq X Series Sequencing v1.0 workflow.

  • Label Group = same as the Index Adapter Kit selected in the ACT that is being used

  • Sequencing Instrument = NovaSeq X Series

On exit from the step, the Routing Script automation is triggered. This automation assigns samples to the first step of the NovaSeq X Series Sequencing v1.0 workflow, Assign Analysis Configuration Template (NovaSeq X Series Sequencing v1.0).

Protocol: NovaSeq X Series Sequencing v1.0

The NovaSeq X Series Sequencing v1.0 protocol consists of the following steps:

  • Assign Analysis Configuration Template (NovaSeq X Series Sequencing v1.0)

  • Make Bulk Pool (NovaSeq X Series Sequencing v1.0)

  • Dilute and Denature (NovaSeq X Series Sequencing v1.0)

  • Load To Library Tube Strip (NovaSeq X Series Sequencing v1.0)

  • AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0)

Each step contains a script to register the start time (upon step entry) and the time that the step is completed (upon step exit). This information is published to CLPA through ICA. These scripts are used only for CLPA support and can be incorporated as part of an automation that performs other functions.

Step 1: Assign Analysis Configuration Template (NovaSeq X Series Sequencing v1.0)

  1. In Lab View, locate the NovaSeq X Series Sequencing v1.0 protocol. The samples are queued for the Assign Analysis Configuration Template (NovaSeq X Series Sequencing v1.0) step.

  2. Add the samples to the Ice Bucket and select View Ice Bucket.

  3. On the Ice Bucket screen, select Begin Work to start the Validate Sample Names and Retrieve Analysis Configuration Template List and Register Step Started automation.

    The automation checks that the sample names do not use restricted characters and are within character limits and retrieves the list of ACTs that you can select. The automation also registers the start time of the step by publishing messages to CLPA through ICA. The part of the script for start time registration is used only for CLPA support.

  4. [Optional] Under Step Details, select Retrieve ACT Information to trigger the Retrieve ACT Information automation.

    This automation retrieves ACT information (e.g., Library Prep Kit, Index Adapter Kit, Reference Genome, and so on) and populates the fields in Clarity LIMS. These details are saved to the ACTMetadata.csv file that you can download. If you are not sure of the analysis configuration before starting the sequencing and analysis run, refer to the details in the file.

  5. Select Next Steps to assign the ACT to the samples.

    This action triggers the Validate Reagent Labels and Apply Selected ACT to Samples and Set Next Step automation. This automation validates that the indexes applied to the libraries are valid for the selected ACT and assigns samples to it. All samples added to the Ice Bucket (mentioned above) are assigned to this ACT.

  6. Select Finish Step.

To use multiple ACTs in a single run, repeat 2–7 for each ACT. For step 2, only add samples that are being assigned to that ACT into the Ice Bucket.

Step 2: Make Bulk Pool (NovaSeq X Series Sequencing v1.0)

  1. In Lab View, locate the NovaSeq X Series Sequencing v1.0 protocol. The samples are queued for the Make Bulk Pool (NovaSeq X Series Sequencing v1.0) step.

  2. Add the samples to the Ice Bucket and select View Ice Bucket.

  3. On the Ice Bucket screen, select Begin Work.

  4. Create a pool of samples as follows.

    1. On the Pooling screen, create a pool by dragging samples into the Pool Creator.

    1. Enter a name for your pool or accept the default name (Pool #1).

    1. [Optional] If multiple pools are required, select the plus sign (+) next to Pool Creator to create a pool.

    1. [Optional] To remove a pool, select the X in the top right corner of the pool.

    2. Select Record Details to trigger the Validate Analysis Configurations automation.

      This automation performs the following checks on the analysis configuration for each pool:

      • Pooled samples are within the maximum configuration limit.

      • Pooled samples have the sample type of analysis (Cloud or Local).

      • Pooled samples that have the same secondary analysis also have the same analysis version and settings.

  5. On the Record Details screen, navigate to the Reagent Lot Tracking section to track the lot information used in the step.

  1. In the Step Details area, complete the following required fields:

    • Number of Lanes to Sequence — Used in volume calculations, to make sure that the volumes are sufficient for the number of times the pool is sequenced. This field is applied to all pools in the step.

    • Final Loading Concentration (pM) — The final loading concentration of the pool in the flow cell.

    • Final Loading Volume (ul) — The final loading volume of the pool in the flow cell. This field is prepopulated with the configured default value (200 ul), but can be edited if more volume is required.

    • Minimum Per Sample Volume (ul) — The minimum volume for each sample. This field is prepopulated with the configured default value (2 ul) and can be edited. If the per sample volume is below the value set in this field, the Calculate Volumes script applies a rounding factor to affected samples so that the volume reaches the minimum volume.

    • % PhiX (2.0nM) Spike-In — The value entered in this field is used to calculate the volume of PhiX spike-in required.

    • Flowcell Type — This is a read-only field configured with the default value of B3.

  2. Select Calculate Volumes to trigger the Calculate Volumes automation.

    This automation calculates the volumes required for each library to form a pool that has the concentration and volume specified in the Step Details fields. The automation is applied to control samples when they are indexed and molarity is specified. It also generates the calculation file in a CSV format which is available for download under Files placeholder section below.

  3. In the Sample Details table, select the pool next to the sample name to view details on the pool composition.

  1. Select Next Steps to trigger the Set Next Step automation.

    This automation sets the next step for samples to ADVANCE, which moves them to the Dilute and Denature (NovaSeq X Series Sequencing v1.0) step.

  2. Select Finish Step.

Step 3: Dilute and Denature (NovaSeq X Series Sequencing v1.0)

  1. In Lab View, locate the NovaSeq X Series Sequencing v1.0 protocol. The pool of samples queued for the Dilute and Denature (NovaSeq X Series Sequencing v1.0) displays.

  2. Add the pool to the Ice Bucket and select View Ice Bucket.

  3. [Optional] On the Ice Bucket screen, set the number of derivatives to create (placed into the library tube strip) and select Begin Work.

    • On entry to the step, the Validate Inputs Flowcell Type and Register Step Started automation is triggered. This automation makes sure that the configured flow cell type is valid. The automation also registers the start time of the step by publishing messages to CLPA through ICA. The portion of the script used for start time registration is used only for CLPA support.

    • On entry to the Record Details screen, the Calculate Volumes automation is triggered. This automation sets the following values:

      • BP Aliquot Volume (ul)

      • RSB Volume (ul)

      • NaOH Volume (ul)

      • TT2 Volume (ul)

      • The automation also generates the calculation file (CSV) and attaches it to the step. This file contains information about the volume of RSB, NaOH, and TT2 to add per working pool.

  4. On the Record Details screen, perform the following actions:

    1. In the Reagent Lot Tracking section, select from the active lots displayed in each drop-down list.

    2. In the Sample Details table, the BP aliquot, RSB, NaOH, and TT2 reagent volume values are auto populated and read-only.

    3. [Optional] In the Sample Details table, select the pool icon to view details of the working pool composition.

      The working pool number is appended to the bulk pool name so that you can identify which working pools are derived from the same bulk pool.

  5. In the Files area, download the Calculation File (CSV) and open it and view details on the RSB, NaOH, and TT2 volumes to add per working pool.

  6. Select Next Steps.

  7. Select Finish Step.

Step 4: Load to Library Tube Strip (NovaSeq X Series Sequencing v1.0)

  1. In Lab View, locate the NovaSeq X Series Sequencing v1.0 protocol. The pool of samples are queued for the Load to Library Tube Strip (NovaSeq X Series Sequencing v1.0) step.

  2. Add the pools to the Ice Bucket and select View Ice Bucket.

  3. On the Ice Bucket screen, select Begin Work to trigger the Validate Analysis Configurations and Register Step Started automation.

    Validate Analysis Configurations automation performs the following basic checks on the analysis configuration for each pool:

    • Pooled samples are within the maximum configuration limit.

    • Pooled samples have the sample type of analysis (Cloud or Local).

    • Pooled samples that have the same secondary analysis also have the same analysis version and settings.

    Register Step Started automation registers the start time of the step by publishing messages to CLPA through ICA. The portion of the script used for start time registration is used only for CLPA support.

  4. On the Placement screen, do as follows.

    1. Drag the pool into the Library 8-tube Strip in the Placed Samples area on the right.

    2. Scan or type the barcode of the Library 8-tube Strip into the Library 8-tube Strip container name field.

    1. Select Record Details.

    After exiting the Placement screen, the Validate Library Strip Tube Barcode automation makes sure that the library tube strip barcode conforms to the barcode mask LC[0-9]{7}-LC1.

  5. The fields displayed on the Record Details screen are used to create the planned run and generate the sample sheet.

    The analysis related information for the planned run is from the ACT associated with the samples and no further analysis configuration is required. Refer to the following table for details.

    Fields Displayed on Record Details Screen of Load to Library Tube Strip (NovaSeq X Series Sequencing v1.0) Step

    Field

    Value

    Run Name

    Enter the experiment name. Only alphanumeric characters, dashes, and underscores are permitted. No spaces.

    Run Mode

    The selected Run Mode must correspond to the ACT type. Presets

    • Local¹

    • Cloud²

    Read 1 Cycles

    Presets

    • 151

    • 101

    • 51

    • Type a custom value

    Read 2 Cycles

    Presets

    • 151

    • 101

    • 51

    • Type a custom value

    Index 1 Cycles

    Presets

    • 0

    • 6

    • 8

    • Type a custom value³

    Index 2 Cycles

    Presets

    • 0

    • 6

    • 8

    • Type a custom value³

    ¹ The Run/Analysis configuration is imported manually to the NovaSeq X Series instrument through a sample sheet. The sample sheet generated on this step is downloaded and imported manually by the user on NovaSeq X Control Software to start the run. The downstream secondary analysis is done using the onboard DRAGEN module.

    ² The planned run configuration is downloaded to the NovaSeq X Series Instrument Control Software to start the run. The downstream secondary analysis is done on the cloud.

    ³ The custom value must correspond to the longest index sequence of the samples in the pools in the library tube strip. Otherwise, the planned run creation fails and an error message displays.

  6. Select Validate Run Setup and Create Planned Run to trigger the automation script. The script performs the following actions:

    • Validates the parameters entered on the Record Details screen.

    • Clarity consolidates sample/library information, run and analysis configuration details and send them to ICA to create a planned run and samplesheet for Cloud run mode.

    • Clarity consolidates sample/library information, run and analysis configuration details and send them to ICA to generate samplesheet for Local run mode.

  7. Select Next Steps.

    On the Assign Next Steps screen, the next step for the pooled samples is set to the AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0) step.

  8. To use multiple ACTs in a single run, repeat steps 1–3 for each ACT. The pool of samples (for different ACTs) are then queued for the Load to Library Tube Strip (NovaSeq X Series Sequencing v1.0) step to be added to the Ice Bucket.

Step 5: AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0)

This protocol contains the AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0) step. This step is fully automated.

Do not add samples to the Ice Bucket or start or complete the AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0) step. The integration does this automatically.

The integration starts the step automatically and data from the run is parsed back into Clarity LIMS. User interaction is not required, but you can review the stages of the step in Clarity LIMS.

Review Run Data

Read summary metrics are recorded for the library pool. After the run is complete, open the step and review these metrics in the Step Details section and the Sample Details table.

Step Details Section

The following values populate the master step fields:

  • Run Name

  • Run Status

  • Output Folder

  • Current Read

  • Current Cycle

  • Library Tube Barcode

  • Flow Cell ID

  • Flow Cell Side

  • Flow Cell Type

  • Flow Cell Part Number

  • Flow Cell Lot Number

  • Flow Cell Expiration Date

  • Instrument ID

  • Instrument Type

  • Instrument Control Software Version

  • Sequencing Log

Sample Details Table

Summary metrics populate the following global custom fields:

  • % Bases >=Q30 R1

  • % Bases >=Q30 R2

  • % Error Rate R1

  • % Error Rate R2

  • Yield (Gb) R1

  • Yield (Gb) R2

  • Reads PF R1

  • Reads PF R2

  • %PF R1

  • %PF R2

  • % Aligned R1

  • % Aligned R2

  • % Phasing R1

  • % Phasing R2

  • % Prephasing R1

  • % Prephasing R2

  • Intensity Cycle 1 R1

  • Intensity Cycle 1 R2

  • Cluster Density R1

  • Cluster Density R2

Troubleshooting

Automated Step Does Not Start

If the AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0) step does not start, Clarity LIMS is likely not receiving sequencing run events from BaseSpace Sequence Hub correctly. Check for the following issues:

  1. Make sure that the NovaSeq X Control Software is configured properly as follows.

    1. Before you start the run, in the NovaSeq X Control Software, select the appropriate BaseSpace Sequence Hub region in the Hosting location drop-down list.

    1. Under Run Settings, check the boxes next to Cloud run monitoring and Cloud run storage.

    If there are issues after modifying the configuration settings on the NovaSeq X Control Software, contact Illumina Support.

Automated Step Starts, But Does Not Complete

If the AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0) step starts, but does not complete, do as follows.

  1. Log in to Clarity LIMS and use one of the following methods to open the in-progress step:

    1. In Lab View, find the step in the Recent Activities pane.

    2. Search for the step in Clarity LIMS using the library tube strip barcode as the search term.

  2. On the Record Details screen, the Sequencing Log multiline text field contains logging information.

    If unable to reach the Record Details screen, or if the Sequencing Log field does not contain enough information to resolve the issue, contact Illumina Support. Provide the relevant information from the troubleshooting steps already performed.

Validate Analysis Configuration Automation Check Fails

The Validate Analysis Configuration automation check is in the Make Bulk Pool (upon pooling) and Load to Library Tube Strip (upon step entry) steps. If a failure happens, an error message displays and the step can be aborted, or you might be prevented from continuing the step. This check can fail for the following reasons:

  • The analysis configuration after library pooling or during the planned run creation exceeds the configuration limit.

    Resolve this error as follows.

    • If the error occurs on the Make Bulk Pool step, reduce the number of analysis configurations for a pool. To reduce the number, reorganize the samples for the pooling step (eg, by pooling samples that have similar configurations together).

    • If the error occurs on the Load to Library Tube step, reduce the number of analysis configurations for the planned run by reorganizing the samples for multiple runs instead of a single run.

  • ACTs of samples in the same pool or planned run must have the same run mode (Local or Cloud).

    Resolve this error as follows.

    1. Abort the step and remove samples with ACTs that have conflicting run modes from the Ice Bucket.

    2. Make sure that all remaining samples in the Ice Bucket have ACTs with the same run modes.

    3. Select Begin Work to continue the step.

  • ACTs of samples in the same pool or planned run that have the same secondary analysis must have the same analysis version.

    Resolve this error as follows.

    • If the error occurs on the Make Bulk Pool step, pool the samples again. Make sure that samples with the same secondary analysis, but conflicting analysis versions, are in different pools.

    • If the error occurs on the Load to Library Tube step, reorganize the samples for the planned run. Make sure that samples with the same secondary analysis, but conflicting analysis versions, are in different runs.

  • ACTs of samples in the same pool or planned run that have the same secondary analysis must have the same analysis settings. The analysis setting fields can differ for a different secondary analysis and are configured in BaseSpace Sequence Hub when the ACT is created.

    Resolve this error as follows.

    • If the error occurs on the Make Bulk Pool step, pool the samples again. Make sure that samples with the same secondary analysis, but conflicting analysis settings, are in different pools.

    • If the error occurs on the Load to Library Tube Strip step, reorganize the samples for the planned run. Make sure that samples with the same secondary analysis, but conflicting analysis settings, are in different runs.

Revision History

Version

Changes

2

  • Updated Step 2: Make Bulk Pool (NovaSeq X Series Sequencing v1.1) to remove instructions on adding control. PhiX control should be added via the % PhiX (2.0nM) Spike-In step field.

1

  • Initial release.

You must create the Analysis Configuration Templates (ACTs) that are required for configuring secondary analysis in the NovaSeq X Series Sequencing v1.0 workflows. Create and delete ACTs in BaseSpace Sequence Hub. For instructions, refer to the BaseSpace Sequence Hub Online Help on the .

Follow the steps in to run the Library Prep Validation workflow with the following:

Select the applicable ACT to assign to the samples. The index adapter kit specified by the ACT must correspond with the label group used in .

[Optional] Create a new lot. For more information, refer to Add and Configure Reagent Kits and Lots in the .

On the Record Details screen, the Reagent Lot Tracking section tracks the NaOH, Resuspension Buffer, and TT2 reagents used in the step. To add and activate reagent lots, refer to Add and Configure Reagent Kits and Lots in the .

Select Finish Step to advance the pooled samples to the AUTOMATED - Sequencing Run (NovaSeq X Series Sequencing v1.0) step. For more information on how to start the sequencing run for different run modes, refer to .

If an automation trigger does not appear to run its corresponding scripts, refer to the Troubleshooting Automation section in the .

Clarity LIMS (Clarity & LabLink Reference Guide) documentation
Illumina Adapter Sequences
Illumina support site
Library Prep Validation Protocol
Clarity LIMS (Clarity & LabLink Reference Guide) documentation
Clarity LIMS (Clarity & LabLink Reference Guide) documentation
NovaSeq X Series Integration v1.1.0 Configuration
Clarity LIMS (API & Database) documentation
Library Prep Protocol