DNA Library Prep v1.1
Overview
The DNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel is part of the AmpliSeq for Illumina TCR beta-SR Panel protocols which include the following functionality:
- Preconfigured AmpliSeq for Illumina TCR beta-SR Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of total RNA using the AmpliSeq™ for Illumina® workflow. 
- Automated calculation of sample and buffer volumes. 
- Automated calculation or display of reagents at every step in the protocol. 
- Automatic step transition when required.Automatic placement of samples when necessary. 
- Automated assignment of QC Pass/Fail, based on user-selected threshold values. 
Protocol 1: DNA Library Prep (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
Protocol Type = Library Prep
Next Steps Configuration

Step 1: Dilute DNA (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Desired Concentration (ng/uL) - Numeric - Range = 20 To 50 
- Decimal Places Displayed = 0 
 - Directions - Multiline Text - Read Only - Default = If enough DNA is available, dilute to intermediate concentration of ~20-50 ng/uL. 
 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Input Amount (ng) - Numeric - Decimal Places Displayed = 0 - Derived Sample - Low TE (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Sample Name - Built-in - Derived Sample - Sample Volume (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Total Volume (uL) - Numeric - Decimal Places Displayed = 2 
 
Step 2: Qubit (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Qubit (AmpliSeq for Illumina v1.1) 
- Step Type = Standard QC 
- Measurement Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Criteria 1 - Operator - Text - Default = >= - Criteria 1 - Source Data Field - Text - Default = Concentration - Criteria 1 - Threshold Value - Numeric - Criteria 2 - Operator - Text - Default = <= - Criteria 2 - Source Data Field - Text - Default = Concentration - Criteria 2 - Threshold Value - Numeric 
- Step File Placeholders - Log - Automatically attached 
- QC Log File - Automatically attached 
- QC Result File - Automatically attached 
- Upload File - Manually uploaded 
 
- Sample Table - Enable QC Flags = Yes 
- Sample Display Default = Expand 
- Well Sort Order = Row 
- File Column Options - File Column Display = Hide 
- File Attachment Method = Auto 
 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Sample Name - Built-in - Measurement - Concentration - Numeric - Decimal Places Displayed = 2 - Measurement - Conc. Units - Text 
 
Step 3: Dilute DNA to Final Concentration (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Desired Concentration (ng/uL) - Numeric - Range = 20 To 50 
- Decimal Places Displayed = 0 
 - Directions - Multiline Text - Read Only - Default = If enough DNA is available, dilute to intermediate concentration of ~20-50 ng/uL. 
 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Input Amount (ng) - Numeric - Decimal Places Displayed = 0 - Derived Sample - Low TE (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Sample Name - Built-in - Derived Sample - Sample Volume (uL) - Numeric - Decimal Places Displayed = 2 - Derived Sample - Total Volume (uL) - Numeric - Decimal Places Displayed = 2 
 
Step 4: Amplify DNA Targets (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Amplify Targets (AmpliSeq for TCRbeta-SR Panel) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
- Reagent Kits - 5x AmpliSeq TCR beta-SR Panel - Supplier = Illumina 
- Catalog Number = 20031675 
- Website = www.illumina.com 
 
- AmpliSeq Library PLUS for Illumina - Supplier = Illumina 
- Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103 
- Website = www.illumina.com 
 
 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - PCR Cycles - Numeric - Decimal Places Displayed = 0 - Recommended Prep Input (ng) - Multiline Text - Read Only - Default = This protocol supports 1-1000 ng. The recommended input is 100 ng high-quality DNA. - Thermal Cycler Program - Text - Default = AMP 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - 5X AmpliSeq HiFi Mix (uL) - Numeric - Decimal Places Displayed = 1 
 - Derived Sample - 5X AmpliSeq TCR beta-SR Panel (uL) - Numeric - Derived Sample - Concentration - Numeric - Required Field - Decimal Places Displayed = 2 
 - Derived Sample - Conc. Units - Text - Required Field - Derived Sample - Input Amount (ng) - Numeric - Decimal Places Displayed = 0 
 - Derived Sample - Nuclease-free water (uL) - Numeric - Decimal Places Displayed = 2 
 - Derived Sample - Prep Input Amount (ng) - Numeric - Required Field - Range = 2 To 200 
- Decimal Places Displayed = 0 
 - Derived Sample - Prep Input Volume (uL) - Numeric - Decimal Places Displayed = 2 
 - Derived Sample - Sample Name - Built-in - Derived Sample - Total Volume (uL) - Numeric - Decimal Places Displayed = 2 
 - Project - Project Name - Built-in 
 
Step 5: Transfer RNA and DNA Amplicons (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Transfer RNA and DNA Amplicons (AmpliSeq for Illumina) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Placement = Enabled
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
- Placement Pattern = Row 
 
- Destination Containers - 96 well plate 
 
Record Details
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Step 6: Partially Digested Amplicons (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Partially Digested Amplicons (AmpliSeq for Illumina v1.1) 
- Step Type = No Outputs 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Thermal Cycler Program - Text - Default = FUPA 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Step 7: Ligate Indexes (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Ligate Indexes (AmpliSeq for Illumina v1.1) 
- Step Type = Add Labels 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
- Reagent Kits - AmpliSeq Library PLUS for Illumina - Supplier = Illumina 
- Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103 
- Website = www.illumina.com 
 
 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Placement = Enabled
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
- Placement Pattern = Row 
 
- Destination Containers - 96 well plate 
 
Add Labels
- Label Groups - AmpliSeq CD Indexes Set A for Illumina 
- AmpliSeq CD Indexes Set B for Illumina 
- AmpliSeq CD Indexes Set C for Illumina 
- AmpliSeq CD Indexes Set D for Illumina 
- AmpliSeq UD Indexes for Illumina (24 Indexes) 
 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - Thermal Cycler Program - Text - Default = LIGATE 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Derived Sample - AmpliSeq Workflow - Text Dropdown - Required Field - Preset - Standard Workflow 
- Equalizer Workflow 
 - Derived Sample - Sample Name - Built-in 
 
Step 8: Clean Up Library (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1) 
- Step Type = No Outputs 
- Reagent Kits - Agencourt AMPure XP Beads - Supplier = Thermo 
- Catalog Number = NC9959336; NC9933872 
 
 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - 70% EtOH Prep Date - Date 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Step 9: Amplify Library (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1) 
- Step Type = No Outputs 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - 1X Lib AMP Mix (uL) - Numeric - Decimal Places Displayed = 2 - 10X Library Amp Primers (uL) - Numeric - Decimal Places Displayed = 2 - Thermal Cycler Program - Text Dropdown - Custom Entries - Presets - AMP_7 
- EQUAL 
- AMP 
 - Total Samples - Numeric - Default = 0 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Expand 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Step 10: Perform Second Clean Up (AmpliSeq for Illumina TCR beta-SR Panel v1.1)
- Master Step Name = Perform Second Clean Up (AmpliSeq for Illumina v1.1) 
- Step Type = Standard 
- Derived Sample Generation = Fixed, 1 
- Naming Convention = {InputItemName} 
Automations

Queue/Ice Bucket
- Defaults - Sample Grouping = Group by Containers 
- Well Sort Order = Row 
 
- Sample Table (Column Headers) - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Derived Sample - Waiting - Built-in - Project - Project Name - Built-in 
Record Details
- Step Data (Master Step Fields) - Field Name - Field Type - Options - Additional Options and Dropdown Items - 70% EtOH Prep Date - Date 
- Step File Placeholders - Log - Automatically attached 
 
- Sample Table - Sample Display Default = Collapse 
- Well Sort Order = Row 
- Table Columns - Global Fields - Category - Field Name - Field Type - Options - Additional Options and Dropdown Items - Container - Container Name - Built-in - Container - LIMS ID (Container) - Built-in - Container - Well - Built-in - Derived Sample - Sample Name - Built-in - Project - Project Name - Built-in 
 
Last updated
Was this helpful?