Skip to content
For the complete documentation index, see llms.txt. This page is also available as Markdown.

DNA Library Prep v1.1

Overview

The DNA Library Prep AmpliSeq for Illumina TCR beta-SR Panel is part of the AmpliSeq for Illumina TCR beta-SR Panel protocols which include the following functionality:

  • Preconfigured AmpliSeq for Illumina TCR beta-SR Panel protocol that supports the preparation of up to 96 uniquely indexed libraries of total RNA using the AmpliSeq™ for Illumina® workflow.

  • Automated calculation of sample and buffer volumes.

  • Automated calculation or display of reagents at every step in the protocol.

  • Automatic step transition when required.Automatic placement of samples when necessary.

  • Automated assignment of QC Pass/Fail, based on user-selected threshold values.

Protocol 1: DNA Library Prep (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

Protocol Type = Library Prep

Next Steps Configuration

Step 1: Dilute DNA (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Copy Concentration and Set Sample Volume
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Calculate Input Amount
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step - Advance
  • Trigger Location = Not Used

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Desired Concentration (ng/uL)

    Numeric

    • Range = 20 To 50

    • Decimal Places Displayed = 0

    Directions

    Multiline Text

    Read Only

    • Default = If enough DNA is available, dilute to intermediate concentration of ~20-50 ng/uL.

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Low TE (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Sample Volume (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 2: Qubit (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Qubit (AmpliSeq for Illumina v1.1)

  • Step Type = Standard QC

  • Measurement Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Assign QC flags (Qubit QC)
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step and Copy Concentration
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Criteria 1 - Operator

    Text

    Default = >=

    Criteria 1 - Source Data Field

    Text

    Default = Concentration

    Criteria 1 - Threshold Value

    Numeric

    Criteria 2 - Operator

    Text

    Default = <=

    Criteria 2 - Source Data Field

    Text

    Default = Concentration

    Criteria 2 - Threshold Value

    Numeric

  • Step File Placeholders

    • Log - Automatically attached

    • QC Log File - Automatically attached

    • QC Result File - Automatically attached

    • Upload File - Manually uploaded

  • Sample Table

    • Enable QC Flags = Yes

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • File Column Options

      • File Column Display = Hide

      • File Attachment Method = Auto

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Sample Name

      Built-in

      Measurement

      Concentration

      Numeric

      Decimal Places Displayed = 2

      Measurement

      Conc. Units

      Text

Step 3: Dilute DNA to Final Concentration (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Dilute DNA (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Copy Concentration and Set Sample Volume
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Calculate Input Amount
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Desired Concentration (ng/uL)

    Numeric

    • Range = 20 To 50

    • Decimal Places Displayed = 0

    Directions

    Multiline Text

    Read Only

    • Default = If enough DNA is available, dilute to intermediate concentration of ~20-50 ng/uL.

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      Concentration

      Numeric

      Required Field

      Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      Decimal Places Displayed = 0

      Derived Sample

      Low TE (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Sample Volume (uL)

      Numeric

      Decimal Places Displayed = 2

      Derived Sample

      Total Volume (uL)

      Numeric

      Decimal Places Displayed = 2

Step 4: Amplify DNA Targets (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Amplify Targets (AmpliSeq for TCRbeta-SR Panel)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • 5x AmpliSeq TCR beta-SR Panel

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Concentration,Total Volume and Input Amount - TCRbeta
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Calculate Prep Input - TCR beta SR
  • Trigger Location = Record Details

  • Trigger Style = Manual button

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    PCR Cycles

    Numeric

    Decimal Places Displayed = 0

    Recommended Prep Input (ng)

    Multiline Text

    Read Only

    Default = This protocol supports 1-1000 ng. The recommended input is 100 ng high-quality DNA.

    Thermal Cycler Program

    Text

    Default = AMP

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      5X AmpliSeq HiFi Mix (uL)

      Numeric

      • Decimal Places Displayed = 1

      Derived Sample

      5X AmpliSeq TCR beta-SR Panel (uL)

      Numeric

      Derived Sample

      Concentration

      Numeric

      Required Field

      • Decimal Places Displayed = 2

      Derived Sample

      Conc. Units

      Text

      Required Field

      Derived Sample

      Input Amount (ng)

      Numeric

      • Decimal Places Displayed = 0

      Derived Sample

      Nuclease-free water (uL)

      Numeric

      • Decimal Places Displayed = 2

      Derived Sample

      Prep Input Amount (ng)

      Numeric

      Required Field

      • Range = 2 To 200

      • Decimal Places Displayed = 0

      Derived Sample

      Prep Input Volume (uL)

      Numeric

      • Decimal Places Displayed = 2

      Derived Sample

      Sample Name

      Built-in

      Derived Sample

      Total Volume (uL)

      Numeric

      • Decimal Places Displayed = 2

      Project

      Project Name

      Built-in

Step 5: Transfer RNA and DNA Amplicons (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Transfer RNA and DNA Amplicons (AmpliSeq for Illumina)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Placement = Enabled

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

    • Placement Pattern = Row

  • Destination Containers

    • 96 well plate

Record Details

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 6: Partially Digested Amplicons (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Partially Digested Amplicons (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Thermal Cycler Program

    Text

    Default = FUPA

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 7: Ligate Indexes (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Ligate Indexes (AmpliSeq for Illumina v1.1)

  • Step Type = Add Labels

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

  • Reagent Kits

    • AmpliSeq Library PLUS for Illumina

      • Supplier = Illumina

      • Catalog Number = 24 - 20019101; 96 - 200191102; 384 - 200191103

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Route AmpliSeq Samples - Immune Repertoire Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - BRCA
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Childhood Cancer Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - CHP v2
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - CP
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Custom DNA Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Focus Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Immune Response Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples - Myeloid Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Route AmpliSeq Samples -Transcriptome Human GEx Panel
  • Trigger Location = Not Used

ℹ The workflow version and step version for the routing script may vary depending on the version of the IPP.

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Placement = Enabled

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

    • Placement Pattern = Row

  • Destination Containers

    • 96 well plate

Add Labels

  • Label Groups

    • AmpliSeq CD Indexes Set A for Illumina

    • AmpliSeq CD Indexes Set B for Illumina

    • AmpliSeq CD Indexes Set C for Illumina

    • AmpliSeq CD Indexes Set D for Illumina

    • AmpliSeq UD Indexes for Illumina (24 Indexes)

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Thermal Cycler Program

    Text

    Default = LIGATE

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Derived Sample

      AmpliSeq Workflow

      Text Dropdown

      Required Field

      Preset

      • Standard Workflow

      • Equalizer Workflow

      Derived Sample

      Sample Name

      Built-in

Step 8: Clean Up Library (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Clean Up Library (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

  • Reagent Kits

    • Agencourt AMPure XP Beads

      • Supplier = Thermo

      • Catalog Number = NC9959336; NC9933872

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    70% EtOH Prep Date

    Date

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 9: Amplify Library (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Amplify Library (AmpliSeq for Illumina v1.1)

  • Step Type = No Outputs

Automations

Count Samples and Calculate Master Mix
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon entry

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Calculate Total Samples and Calculate Master Mix
  • Trigger Location = Not Used

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    1X Lib AMP Mix (uL)

    Numeric

    Decimal Places Displayed = 2

    10X Library Amp Primers (uL)

    Numeric

    Decimal Places Displayed = 2

    Thermal Cycler Program

    Text Dropdown

    Custom Entries

    Presets

    • AMP_7

    • EQUAL

    • AMP

    Total Samples

    Numeric

    Default = 0

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Expand

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Step 10: Perform Second Clean Up (AmpliSeq for Illumina TCR beta-SR Panel v1.1)

  • Master Step Name = Perform Second Clean Up (AmpliSeq for Illumina v1.1)

  • Step Type = Standard

  • Derived Sample Generation = Fixed, 1

  • Naming Convention = {InputItemName}

Automations

Set Next Step - Advance
  • Trigger Location = Record Details

  • Trigger Style = Automatic upon exit

Queue/Ice Bucket

  • Defaults

    • Sample Grouping = Group by Containers

    • Well Sort Order = Row

  • Sample Table (Column Headers)

    Category

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    Container

    Container Name

    Built-in

    Container

    LIMS ID (Container)

    Built-in

    Container

    Well

    Built-in

    Derived Sample

    Sample Name

    Built-in

    Derived Sample

    Waiting

    Built-in

    Project

    Project Name

    Built-in

Record Details

  • Step Data (Master Step Fields)

    Field Name

    Field Type

    Options

    Additional Options and Dropdown Items

    70% EtOH Prep Date

    Date

  • Step File Placeholders

    • Log - Automatically attached

  • Sample Table

    • Sample Display Default = Collapse

    • Well Sort Order = Row

    • Table Columns - Global Fields

      Category

      Field Name

      Field Type

      Options

      Additional Options and Dropdown Items

      Container

      Container Name

      Built-in

      Container

      LIMS ID (Container)

      Built-in

      Container

      Well

      Built-in

      Derived Sample

      Sample Name

      Built-in

      Project

      Project Name

      Built-in

Last updated

Was this helpful?